radius-authentication-server dead-time x
command is used to specify Dead
Time of Common Servers. “
x
” is the Dead Time with a number between 0
and 3600 seconds.
The Dead Time is the period during which the switch will not send new
requests to a server that has failed to respond to a previous request. This will
stop the switch from continually trying to contact a server that it has already
determined as dead.
Setting the Dead Time to a value greater than 0 (zero) will enable this feature,
but only if more than one server has been configured.
radius-authentication-server timeout x
command is used to specifies Time
Out of Common Servers. “
x
” is the Timeout with a number between 3 and
3600 seconds. The Timeout is the maximum time to wait for a reply from a
server.
If the server does not reply within this time frame, we will consider it to be
dead and continue with the next enabled server (if any).
RADIUS servers are using the UDP protocol, which is unreliable by design. In
order to cope with lost frames, the timeout interval is divided into 3
subintervals of equal length. If a reply is not received within the subinterval,
the request is transmitted again. This algorithm causes the RADIUS server to
be queried up to 3 times before it is considered to be dead.
33 rmon command
This function is used to configure RMON function of the switch. This switch
supports RMON group 1(statistics), 2(history), 3(alarm), 9(event). The
following commands are used to configure those RMON groups.
(config)# rmon ?
alarm Add RMON Alarm entry
event Add RMON Event entry
history Add RMON Hisotry entry
statistics Add RMON Statistics entry
Enter “rmon alarm x ?”. The commands for configiring parameters for the
alarm will be sh
own. “x” is the index of the entry. The range is from 1 to
65535.
For example, entering “rmon alarm 10 ?”, the follwing sub-commands
will be shown.
# rmon alarm 10 ?
falling-index Falling event index
falling-threshold Falling threshold value
interval Indicates the interval in seconds for sampling and
comparing the rising and falling threshold
rising-index Rising event index
rising-threshold Rising threshold value
sample-type The method of sampling
Summary of Contents for GSW-3208M1
Page 1: ...1 GSW 3208M1 3216M1 3424M1 L2 Managed GbE Switches ...
Page 176: ...173 ...
Page 185: ...182 ...
Page 213: ...210 This page provides an overview of RMON Event table entries ...
Page 215: ...212 This page provides an overview for LACP statistics for all ports ...
Page 227: ...224 6 4 29 Monitor sFlow This page shows receiver and per port sFlow statistics ...
Page 240: ......