Chapter 4. Test & Diagnostics
29
Loop back test notes:
Use this method to quick test a standalone unit; With the E1
timing source set to internal oscillator, connect the E1 Tx to E1
Rx with a single coaxial cable. Press the Pattern switch. The E1
Tx and Rx circuits will be tested. The E1 signal loss and alarm
LEDs should be off and no test errors should result on the error
LED. Disconnect the Coax cable momentarily. The signal loss,
alarm and error LEDs should all light. Reconnect the cable and
they should all go out. This test may also be performed on the
RJ-48 by making a loop back plug.