Test frequency min.
30 (30 to 180)
Specifies the frequency at which the Solar Test function
should perform.
Winter mode
Off (Off/On)
Winter mode is a setting which does not permit the
EcoZenith to check whether charging of solar energy to
the lower tank is possible.
In winter, the EcoZenith normally retains a higher
temperature and the sun emits less energy and lower
temperatures. To check whether charging of solar
energy to the tank is possible, water must circulate in
the system and the temperatures must be compared. If
the check indicates that charging is not possible, energy
will have been used unnecessarily by having the water
circulate. The winter mode setting prevents this check
“Off” Deactivates the Solar Test Tank function. Charging
is carried out to the bore hole only.
“No” Permits the Solar Test Tank function, and charging
of the EcoZenith is possible.
Flow l/min
6 (1 to 50)
The flow circulating through the solar panels should be
indicated here. (This can be read from the flow meter in
the system unit.) The flow should be read when pump
G30 is running at 100%.
NB:
It is important the value is correct, as the flow
is used as the basis for calculating the power and
cumulative energy. Incorrect flows will therefore produce
incorrect values for these parameters.
Protection Collector
Max. temp. °C
120 (110 to 150)
Protects the solar panels from high temperatures by
allowing circulation in the solar panels even though
the maximum temperature has been reached in the
respective tank. For safety reasons, the temperature in
the EcoZenith is never allowed to exceed 95°C.
Cooling No
(Yes/No)
Permits circulation to the EcoZenith as well as the
bore hole. This is in order to prevent excessively high
temperatures in the solar panels. Applies once the
maximum permitted temperature has been reached.
For safety reasons, the temperature in the EcoZenith is
never allowed to exceed 95°C.
Re-cooling No
(Yes/No)
This option may be activated when the cooling function
has been activated. The function means that the system
endeavours reduce the temperature in the hot water and
buffer tank to the set setpoint (set in the
Re-cooling to
temp. menu). This means that the solar panels are used
as cooling elements for a short period of time.
Protection collector
Max temp °C
120
Cooling Yes
Recooling No
Recooling to temp °C
70
Anti-freeze No
Anti-freeze °C
-25
Summary of Contents for EcoZenith i550 Pro
Page 1: ...162 105 20 1 2013 06 13 Installation and Maintenance Manual CTC EcoZenith i550 Pro...
Page 95: ...97 CTC EcoZenith i550 Pro For the installer...
Page 97: ...99 CTC EcoZenith i550 Pro For the installer 6725 7 1 6 1 287 322 7 36 1 7 5 1 1 D E...
Page 120: ...122 CTC EcoZenith i550 Pro For the installer 20 Wiring diagram main card 3x400V...
Page 121: ...123 CTC EcoZenith i550 Pro For the installer...
Page 122: ...124 CTC EcoZenith i550 Pro For the installer 21 Wiring diagram main card 1x230V...
Page 123: ...125 CTC EcoZenith i550 Pro For the installer...
Page 124: ...126 CTC EcoZenith i550 Pro For the installer 22 Wiring diagram for expansion card...