9.4.3
Operation data solar panels
This menu shows information about solar panels (if
defined in the
Installer/Define system/Solar panels menu).
Status
Solar panel charge tank
Shows status for solar panels:
• Off
Solar panels are in operating mode Off.
•
Solar panel charge tank
The solar panels are charging the Ecozenith’s tank
•
Solar panel update. Vacuum
The solar panels are charging the hot water system.
•
Solar panel charge ground source
The solar panels are charging the ground source.
From solar panels °C
68 (-99...99)
This shows the temperature of the flow supplied from
the solar panels (sensor B31).
To solar panels °C
60 (-99...99)
This shows the temperature of the flow supplied to the
solar panels (sensors B30).
Pump Panel %
46 (0...100)
This shows the current charge as a percentage of
maximum capacity for the pump (G30).
Pump Solar Charge %
46 (0...100)
This shows the current charge as a percentage of
maximum capacity for the pump (G32). Only displayed if
the solar panel is connected via a heat exchanger to the
EcoZenith.
Pump charge brine loop
(On /Off)
This shows the operating mode for the pump (G31) for
recharging the bedrock.
Valve charging Brine loop
(On /Off)
This shows the mode for the valve (Y31) for recharging
the bedrock.
9.4.3.1
Operation data solar panels -
diagram
Operation data for the solar panels for the last 72 hours
is displayed here. The furthest point to the right is the
present. The time “rolls” forward. A red curve indicates
the difference between primary flow and return in the
solar collector. A green curve indicates the power output
from the solar panel. A blue curve indicates the energy
output from the solar panel. At the bottom right the total
energy output from the solar panels is shown. The values
are calculated from incoming and outgoing temperatures
from the solar panels, plus the operating time and set
flow. This is therefore not an exact measurement.
Operation data solar panels
Status
Solar panel charge tank
Outlet °C
68
Inlet °C
60
Pump Panel %
46
Pump Solar Charge %
46
Pump charge brine loop
Off
Valve charging brine loop
Off
Solar panel
16 20 0 4 8 12
16 20 0 4 8 12
12
12
12
12
12
2
12
2
2
12
1
2
12
2
2
2
2
2
1
2
Solar panel
Diff ºC
Effect
Energy
Summary of Contents for EcoZenith i550 Pro
Page 1: ...162 105 20 1 2013 06 13 Installation and Maintenance Manual CTC EcoZenith i550 Pro...
Page 95: ...97 CTC EcoZenith i550 Pro For the installer...
Page 97: ...99 CTC EcoZenith i550 Pro For the installer 6725 7 1 6 1 287 322 7 36 1 7 5 1 1 D E...
Page 120: ...122 CTC EcoZenith i550 Pro For the installer 20 Wiring diagram main card 3x400V...
Page 121: ...123 CTC EcoZenith i550 Pro For the installer...
Page 122: ...124 CTC EcoZenith i550 Pro For the installer 21 Wiring diagram main card 1x230V...
Page 123: ...125 CTC EcoZenith i550 Pro For the installer...
Page 124: ...126 CTC EcoZenith i550 Pro For the installer 22 Wiring diagram for expansion card...