2.11
Cooling CTC EcoComfort
CTC EcoComfort is an accessory which utilises the cool temperatures
of the bore hole to create a cool indoor climate in summer. The extent to
which you can cool a property depends on several factors, such as the
rock temperature available for the case in point, the size of the house, the
capacity of the floor heating or fan convectors, the living area layout, etc.
NOTE: Remember to insulate pipes and connections against condensation.
Combined floor heating/floor cooling
In order to be able to utilise passive cooling, you need to have a floor heating
system to which cooling can be connected. Provided the floor heating
system can be used for cooling the property, the floor heating system is used
for heating in the winter and for cooling in the summer.
Separate heating/radiator system and cooling system
(fan convector)
EcoHeat simultaneously manages a radiator system for heating and a
separate system for cooling. This can be relevant if you want to cool a part
of a property using e.g. a fan convector at the same time as need to heat
another part.
Desired room temperature
The desired room temperature is set on the EcoZenith display. The water
mix is automatically adjusted to achieve the right temperature for the amount
of cooling needed (room sensor deviation). The greater the deviation, the
colder the water fed into the system. Depending on the system in question,
temperatures are not permitted to become too cold (as this can result in
damage due to damp).
NOTE: For cooling it is recommended that the room temperature be set a
few degrees higher than the set temperature for heating operation. Given
that the room temperature tends to increase as the outdoor temperature
increases, the cooling function will cut in.
Note too that cooling capacity depends, among other things, on bore
hole temperature, bore hole length, flows and floor heating/fan convector
capacity, and will vary during the warm part of the year.
See CTC EcoComfort manual for more information.
See also Cooling Menu in the Detail Description Menus chapter
(Installer/Define system/Cooling)
Fan convector
Floor heating
)ORRU
KHDWLQJ
)DQ&RLO
J
%
%
%
%
*
*
*
<
<
Summary of Contents for EcoZenith i550 Pro
Page 1: ...162 105 20 1 2013 06 13 Installation and Maintenance Manual CTC EcoZenith i550 Pro...
Page 95: ...97 CTC EcoZenith i550 Pro For the installer...
Page 97: ...99 CTC EcoZenith i550 Pro For the installer 6725 7 1 6 1 287 322 7 36 1 7 5 1 1 D E...
Page 120: ...122 CTC EcoZenith i550 Pro For the installer 20 Wiring diagram main card 3x400V...
Page 121: ...123 CTC EcoZenith i550 Pro For the installer...
Page 122: ...124 CTC EcoZenith i550 Pro For the installer 21 Wiring diagram main card 1x230V...
Page 123: ...125 CTC EcoZenith i550 Pro For the installer...
Page 124: ...126 CTC EcoZenith i550 Pro For the installer 22 Wiring diagram for expansion card...