9.5.2.3 Elec.
heater
In the “Elec. heater” menu you can make settings
affecting the operation of the immersion heaters.
El.heater upper kW
9 (0...18
Here you select the power that the upper immersion
heaters are allowed to emit.
El.heater lower kW
9 (0...9)
Here you select the power that the upper immersion
heaters are allowed to emit
El.heater lower °C
50(30...60)
Setting of temperature for the lower immersion heater.
The lower immersion heater is only allowed to operate
when the heat pump is blocked for some reason.
Delay mixing valve
180(30...240)
This is where the mixing valve delay is set - the period
before it draws energy from the upper part of the
tank. The mixing valve can be blocked so that it never
retrieves energy from the upper part of the tank.
Main fuse A
20 (16...100)
The property’s main fuse size is set here. This setting and
the fitted current sensors ensure the fuses are protected
when using appliances which generate temporary power
peaks, for example, cookers, ovens, engine heaters etc.
The product temporarily reduces power drawn where
this type of equipment is being used.
Conversion factor curr. sensors
1:1 (1:1...1:10)
This menu contains the factor the current sensor are to
use. This setting is only performed if the connection has
been installed for a current sensor for higher currents.
Example: User (set) value 1:2 => 16 A will be 32 A.
Tariff EL
Off (Off/On)
This indicates whether the product is connected to tariff-
controlled electricity.
Elec. heater
Upper el.heater(s) kW
9
Lower el.heater kW
9
Lower el.heater °C
50
Delay mixing valve
180
Main fuse A
60
Conversion factor curr. sensors
1:1
Tariff, EL
No
Summary of Contents for EcoZenith i550 Pro
Page 1: ...162 105 20 1 2013 06 13 Installation and Maintenance Manual CTC EcoZenith i550 Pro...
Page 95: ...97 CTC EcoZenith i550 Pro For the installer...
Page 97: ...99 CTC EcoZenith i550 Pro For the installer 6725 7 1 6 1 287 322 7 36 1 7 5 1 1 D E...
Page 120: ...122 CTC EcoZenith i550 Pro For the installer 20 Wiring diagram main card 3x400V...
Page 121: ...123 CTC EcoZenith i550 Pro For the installer...
Page 122: ...124 CTC EcoZenith i550 Pro For the installer 21 Wiring diagram main card 1x230V...
Page 123: ...125 CTC EcoZenith i550 Pro For the installer...
Page 124: ...126 CTC EcoZenith i550 Pro For the installer 22 Wiring diagram for expansion card...