69
CTC EcoZenith i350
Compressor
Compressor On
Charge pump
On 47%
Brine pump/Fan
On
HP in/out °C
35.5 / 42.3
Outdoor 7.1
Defrost timer
25.1
Current A
4.0
11.6.3
Compressor
This menu is intended for servicing and advanced
troubleshooting.
Compressor
(On/Off /65 rps)
Shows whether the compressor is operating or not,
as well as showing the compressor speed in rps
(revolutions per second). Speed is only shown for the
inverter-controlled heat pumps.
Charge pump
(On/Off/47%)
Shows the operating status and flow of the charge
pump (G11) as a percentage.
Brine pump
(On/Off)
Shows whether the brine pump (G20) is operating or
not.
HP in/out °C
Shows the heat pump’s return and primary flow
temperatures.