CTC EcoLogic S
Motor protection
CTC EcoLogic constantly monitors the compressor’s operating current and
an alarm is triggered if the compressor is drawing an unusually high current.
When a fault occurs, the message “Motor protect high current” is displayed.
The cause of the fault may be as follows:
• Phase failure or mains interruption. Check the fuses, which are the
most common cause.
• Compressor overload. Call out a service engineer.
• Faulty compressor. Call out a service engineer.
• Circulation too poor between the cooling circuit and cylinder. Check
the heat medium pump (charge pump).
• Abnormally high temperature in the brine circuit. Call out a service
engineer.