![CTC Union 6212576 Installation And Maintenance Manual Download Page 18](http://html1.mh-extra.com/html/ctc-union/6212576/6212576_installation-and-maintenance-manual_2693332018.webp)
18
CTC EcoLogic S
3.3
Settings
3.3.1
Settings Heating Circuit
Menu: "Installer / Settings / Heating Circuit" when controlling
outdoor sensor
.
Example
Inclination 50 means that the temperature to the
external heating tank will be 50 °C when the outdoor
temperature is -15 °C if Adjustment is set to 0. If
Adjustment is set to +5 °C, the temperature will
be 55 °C instead. For all outdoor temperatures the
inclination is increased by 5 °C, i.e. inclination is parallel
displaced by 5 °C.
Menu: "Installer / Settings /".
3.3.1.1
Control on outdoor sensor/
inclination
EcoLogic S controls the charging of the external heating
tank based on the set heat curve. The inclination of
the heat curve indicates the temperature to which the
external heating tank must charge at different outdoor
temperatures.
The outdoor sensor used depends on the type of heat
pump connected to the system:
• Liquid/water heat pump (CTC EcoPart): -
packaged outdoor sensor must be installed
(refer to the "Electrical installation/Connecting the
control card EcoAir/EcoPart" chapter)
• Air/water heat pump (CTC EcoAir): -the existing
outdoor sensor of the heat pump is used.
Max primary fl ow °C
55 (30...80)
Maximum temperature (sensor HP
out
) permitted out to
the external heating tank.
Min primary fl ow °C
14 (14...65)
Minimum temperature (sensor HP
out
) permitted out to
the external heating tank.
Start/stop diff °C
5 (1...30)
This menu is used to set the negative hysteresis before
the heat pump starts charging the external heating
tank after the stop temperature (sensor HP
out
) has been
reached.
Example: If the stop temperature is 55 °C and hysteresis
is set to 5 °C in this menu, it means the heat pump will
start charging again when the temperature has dropped
to 50 °C.
Inclination °C
50 (25...85)
Inclination indicates the temperature the external heating
tank needs at different outdoor temperatures. More
information about this can be found in the "Your home’s
heating settings" chapter.
The value set in this menu is the outgoing fl ow
temperature to radiators when the outdoor temperature
is -15 °C.