-Filter Location / Other Requirements-

• Locate the unit near an unswitched, 120 volt / 60 Hz grounded electrical outlet.
• Check for distance and proper drain installation (e.g. floor drain, washing machine standpipe).
• Determine type and size of piping required for softener connection (e.g. copper, galvanized, PVC plastic).

Note: 

Where the drain line is elevated above the control valve or exceeds 20 feet in length to reach the drain, use 3/4”    

 

I.D. drain line tubing of 1/2” I.D. Drain line tubing is not included.

Caution: 

If sweat soldering copper pipe, (remember to always use lead free solder and flux) cover yoke and bypass valve  

 

   with wet rags to prevent heat damage to connections and control valve! If using PVC or plastic pipe, primers  

 

 

   and solvent cements specifically recommended for use with potable water are required.

Note:

  All plumbing lines not requiring soft water should be connected upstream of the filter. (See Typical Installation  

 

 Diagrams.)

-Installation Procedure-

-Water Supply Connection and Bypass Valve-

To allow for filter servicing, swimming pool filling or lawn sprinkling, a manual bypass valve has been installed at the
factory. The bypass allows raw water to be manually routed around the filter.

1. Position filter at desired location for installation. If a water softener is to be installed, the filter should be positioned first    
    and then the softener. (See Installation Diagrams.)
2. The filter material is shipped separately from the mineral tank. The tank must be loaded with material after tank has  

 

     been placed at the desired location.
 

a. Remove the control valve by unscrewing from the tank.

 

b. Remove and inspect distributor tube and bottom basket.

 

c. Replace distributor tube and use a cork or tape to place over top of distributor tube to prevent mineral from  

 

 

    entering tube while filling.

 

d. Place mineral funnel in hole on top of tank.

 

e. Pour several gallons of water in the tank.

Caution: 

 Not following this procedure can cause damage to distributor tube or basket when loading material!

 

 f. First pour in the filter material.

Note: 

The required quantity of gravel is in the tank already.

 

 g. After filling the tank with material, use a garden hose or several buckets to fill the tank with water.

Note: 

This will permit the filtering material to become soaked while preparing the installation and will prevent the control    

           valve from being plugged with floating material on initial backwash.
 

 h. Remove funnel and clean filter material from tank threads.

 

  i. Remove cork or tape from distributor tube.

 

  j. Replace control valve on mineral tank.

Caution: 

Be extremely careful to position distributor tube into control valve distributor tube pilot hole.

3. Turn off main water supply and open nearest faucet to relieve pressure.
4. Cut main line and install elbows and extensions. Inlet and outlet connections on the control valve are 3/4” FNPT.

Note:

 An optional 1” FNPT bypass is available.

Caution:

 Raised arrows located on the sides of control valve body and bypass valve indicate proper direction of water  

 

 

   flow. Install inlet and outlet piping in direction of arrows.

5. Rotate handle on bypass valve to the bypass position (position of handle is across inlet/outlet piping).
6. Turn the main supply line on to restore water service to the home.
7. Open nearest faucet to evacuate air and repressurize plumbing lines.
8. Check for leaks!

Installation

Summary of Contents for greensand plus IF10-S2

Page 1: ...SIGNATURE 2 SERIES Greensand Plus Iron Filter Manual Installation Operation Manual...

Page 2: ...tion Page 3 Control Start Up Procedures Page 8 Utilizing Bluetooth Page 11 Master Programming Page 12 Powerhead Assembly Page 13 Valve Body Assembly Page 14 Bypass Assembly Page 15 Additional Informat...

Page 3: ...als It is recommended that Teflon tape be used to seal plastic Noryl threaded fittings 2 General Specifications IF10 S2 IF15 S2 IF20 S2 IF25 S2 Filter Media Greensand Plus Filter Media Capacity cu ft...

Page 4: ...ed service The valve then reverses the flow of the water through the filter bed to produce a backwash to the drain Because of the density of the media bed it is very important to size the filter to th...

Page 5: ...o a water heater to prevent damage due to back up of hot water DO NOT install the unit in an area of direct sunlight or where freezing temperatures may occur See Typical Installation Diagram CITY WATE...

Page 6: ...ntrol valve by unscrewing from the tank b Remove and inspect distributor tube and bottom basket c Replace distributor tube and use a cork or tape to place over top of distributor tube to prevent miner...

Page 7: ...emove rubber band from float valve 3 Measure distance from bottom of chemical feed valve to the bottom of float with the float in the UP position To move float slide rubber grommets up and down float...

Page 8: ...ines turn off faucet Initial Control Valve Operation 1 Advance control valve to BACKWASH cycle 1 position and allow water to run to drain for 3 to 4 minutes Warning Close handle on bypass prior to sel...

Page 9: ...ever occur 3 Default setting is 6 days for filters 5 To Exit Main Menu press the Menu Enter button Note If no buttons are pressed for 60 seconds the Main Menu will be exited automatically 8 Control St...

Page 10: ...during this time To confirm that the battery is working press either button and the display will turn on for five 5 seconds If power failure occurs while system is regenerating the Isobar 2 will motor...

Page 11: ...step With Days Remaining Until Next Regeneration at 1 Press and hold the Set Change button After 3 seconds the backwash cycle will begin 3 To Fast Cycle thru regeneration First complete above 2 steps...

Page 12: ...and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for complian...

Page 13: ...ge the digits with the Set Change button and accept with the Menu Enter button After the entire display flashes press the Menu Enter button to move to the next menu item 2 Regeneration Cycle Step Time...

Page 14: ...ad Assy 21003X100 1 1 Softener Circuit Boad Assy 21001X102 1 2 Encoder 20001X124 1 3 Front Plate 20001X004 1 4 Encoder Wheel 20001X007 1 5 Main Gear 20001X120 1 6 Power Supply 20001X125 1 7 Back Plate...

Page 15: ...4 GPM PVC 20251X258 Flow Control Assy 3 0 GPM PVC 20251X259 1 Flow Control Assy 3 5 GPM PVC 20251X260 1 Flow Control Assy 5 0 GPM PVC 20251X262 1 Flow Control Assy 7 0 GPM PVC 20251X264 1 7 Drain Lin...

Page 16: ...SIGNATURE 2 SERIES Bypass Assembly Ref Description Part Qty 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless Steel 20561X283 1 15 1 2...

Page 17: ...p 3 Remove injector assembly Apply silicone lubricant to new injector assembly O rings and install Be sure to push injector assembly tightly so O rings are seated Install a new screen 4 Apply silicone...

Page 18: ...lve manually to assure proper function Make sure control valve is returned to the service position 13 Make sure there is enough salt in the brine tank 14 Start regeneration cycle manually if water is...

Page 19: ...the outer edge of each seal to make sure it is seated When all seals and spacers are seated properly you will have a 1 4 of space between the top seal the the top of the valve body 6 Follow Steps E7...

Page 20: ...water is over it Resin fouling Call dealer Find out how to confirm it Clean the resin and prevent future fouling Poor distribution channeling uneven bed surface Call dealer Check backwash flow Regene...

Page 21: ...connectionsfor air leaks Internal control leak Call dealer Check piston seals and spacers for scratches and dents 9 Continuous Flow to Drain Foreign material in control piston and seals Call dealer C...