SIGNATURE 2 SERIES
Installation
4
-Installation Requirements-
Feed Pot Tank
• A level floor position between the well pump and pressure tank. (See Typical Installation Diagram.)
• DO NOT install in an area of direct sunlight or where freezing temperatures may occur!
Filter Tank
• A level floor position ahead of piping into water heater.
• Unit must be installed at least 10’ ahead of the inlet to a water heater to prevent damage due to back-up of hot
water.
• DO NOT install the unit in an area of direct sunlight or where freezing temperatures may occur! (See Typical Installation
Diagram.)
CITY WATER
INLET
WELL
INLET
RELIEF VALVE
MUST BE
INSTALLED
PRESSURE
TANK
WATER
METER
GREEN-
SAND
PLUS
FILTER
SOFTENER
BRINE TANK
WATER
HEATER
PRESSURE RELIEF VALVE
(To drain)
PUMP
HARD WATER
TO OUTSIDE FAUCETS
HOT SOFT WATER
COLD SOFT WATER
SERVICE
GREENSAND PLUS FILTER
(Incoming Water from Left-Side)
GROUNDED & UNSWITCHED
115- VOLT OUTLET
DRAIN LINES
DRAIN LINES
REQUIRED
4" AIR GAP
FEED POT
TANK