SIGNATURE 2 SERIES
10
Starting Extra Regeneration Cycle
1.
To Start
Delayed Extra Cycle
Example
(
1
)
-
If Days Remaining Until Next Backwash does not read ‘1’, press and hold the
Set/Change
button for 3 seconds until the display reads ‘1’.
-
Backwash cycle will initiate at the next designated backwash time.
2.
To start
Immediate Extra Cycle
First complete above step.
-
With Days Remaining Until Next Regeneration at ‘1’.
-
Press and hold the
Set/Change
button.
-
After 3 seconds, the backwash cycle will begin.
3. To
Fast Cycle
thru regeneration
First complete above 2 steps.
Note
:
Press and hold the
Set/Change
button for 3 seconds to advance to the next cycle step.
Fast Cycle is not necessary unless desired to manually step through each cycle step.
(Repeat until valve returns to the home display)
Control Start-Up Procedures
Filters
Default (Min)
Step 1
Backwash
10
Step 2
Brine Draw
60
Step 3
Rapid Rinse
10
Step 4
Refill
4