Normal Operation
1.
Home Display
a. Alternates between the display of Time of Day and Number of Days until the Next
Backwash. (Metered Softeners will alternate between time of days and gallons
remaining until next regeneration)
- Days Remaining until the Next Backwash will count down from the entered
value until it reaches 1 day remaining.
- A Backwash Cycle will then be initiated at the next designated regeneration
time.
2.
Battery Back-Up
(Uses a standard 9-volt alkaline battery.)
Features of Battery Back-Up:
• During power failures, the battery will maintain the time of day as long as the
battery has power. The display is turned off to conserve battery power during
this time. To confirm that the battery is working, press either button and the
display will turn on for five (5) seconds.
• If power failure occurs while system is regenerating, the Isobar 2
will motor to a shut off position to prevent constant flow to drain. Depending
upon system pressure and other factors, it is possible to observe a reduced flow to
drain during this step. After power is restored, the Isobar 2 will return
and finish the cycle where it left off prior to the power interruption.
• When used without battery back-up, during a power failure, the unit stops at its
current point in the regeneration position and then restarts at that point when the
power is restored. The time will be offset by the increment of time the unit was
without power, so it is necessary to reset the time of day on the unit. No other
system will be affected.
Control Start-Up Procedures