Spare parts list

CHP-305PX Spare parts list

NO

Spare parts list

1

Top cover

34

4-way valve to evaporator piping

2

Ambient temp. sensor

35

Discharge pipe

3

Temperature sensor clip

36

Gas return piping

4

Back grill

37

Pipe

5

Evaporator

38

Low pressure switch

6

Top Frame

39

Filter to liquid storage tank

7

Isolation panel

40

liquid storage tank to EEV

8

Fan motor bracket

41

4-way valve

9

Electric reactor

42

EEV to distribution pipe

10

Fan motor

43

Filter

11

DC motor bushing

44

Exchanger to filter

12

Left panel

45

EEV

13

Fan blade

46

4-way valve to exchanger

14

Ventilation panel

47

Exchanger temperature sensor clip

15

Front panel

48

Water outlet temp. sensor

16

Controller box

49

Rubber ring on water connection

17

Display cover

50

Water flow switch

18

Controller

51

Sealing ring

19

Service panel

52

Red rubber ring

20

Evaporator plate

53

Nut of water connection

21

Base tray

54

Blue rubber ring

22

Liquid storage tank

55

Titanium heat exchanger

23

Compressor

56

Water inlet temp. sensor

24

Compressor heating resistor

57

2 ways terminal blocks

25

Evaporator plate

58

Clip

26

clip

59

3-ways terminal blocks

27

Evaporator temperature sensor

60

WIFI module

28

Pressure gauge

61

PCB

29

Back panel

62

Relay

30

4-way valve coil

63

Electric box cover

31

High pressure switch

64

Driving board

32

Sensor holder

65

Electric box

33

Discharge temp. sensor

66

Filter board

Summary of Contents for CHP075PX

Page 1: ......

Page 2: ...Please read and understand ALL the instructions before installation and use...

Page 3: ...he necessary certification which implies appropriate knowledge of the applicable regulations and standards as well as the necessary competence in emission prevention and recovery of fluorinated greenh...

Page 4: ...an insulated cover is used Please call supplier to discuss INDEX 1 Specification 2 Dimension 3 Stock advice 4 Installation 5 Adjust the by pass kit 6 Initial operation 7 Controller Operation 8 Electri...

Page 5: ...7 8 4 7 8 4 7 8 4 7 8 4 7 8 4 7 Voltage V 220V 240V 50Hz or 60Hz 1PH Rated current A 5 0 6 7 8 2 9 5 11 5 14 9 18 6 22 3 Min MCB fuse A 16 16 16 25 25 30 30 40 Main cable mm2 1 5 2 5 2 5 2 5 4 4 4 6 A...

Page 6: ...4 2 Dimension unit mm 2 1 Model CHP075PX CHP095PX...

Page 7: ...5 2 2 Model CHP115PX CHP135PX CHP165PX 2 3 Model CHP205PX CHP255PX...

Page 8: ...6 2 4 Model CHP305PX...

Page 9: ...a minimum period of 24hrs has passed with the unit upright before the unit can have the electrical power turned on Smoking and the use of flames are prohibited near R32machine Water connections are no...

Page 10: ...the two joints like the picture shows 3 Screw them onto the water Inlet outlet junction NOTE Please check for any shipping moved damaged pipe work etc that is too close to other items that may cause v...

Page 11: ...9 Dry contact timer connection Timer Dry contact pump connection Water pump...

Page 12: ...ter level higher than the circulation pump location Unless a One Way Check Valve is used in the plumbing circuit 8 Typically the pool heat pump unit should be installed aside a pool less than 7 5 mete...

Page 13: ...Installation illustration NOTE The factory only provides the heat pump unit The other items in the illustration are necessary spare parts for the water system which are provided by users or installers...

Page 14: ...critical to the heater s life If an automatic chlorinator or brominator is used it must be located downstream of the heater A ONE way check valve must be installed between the chlorinator and the heat...

Page 15: ...flow through the heat pump How to get the optimum water flow Please turn on the heat pump under heating function firstly close the by pass then open it slowly to start the heat pump the machine can t...

Page 16: ...er temperature drops 2 degree below the set temperature Depending on the initial temperature of the water in the swimming pool and the air temperature it may take several days to heat the water to the...

Page 17: ...on Power Off Ambient 5 5 5 15 15 25 25 35 Water temp Pressure gauge Mpa 0 59 0 85 0 85 1 18 1 18 1 59 1 59 2 1 Unit Condition Running Ambient Water temp 10 15 15 20 20 25 25 30 30 35 Pressure gauge Mp...

Page 18: ...and smart The default mode issmart mode 7 2 4 button Press for 2 seconds to enter secondary page Press and to select the functions and press to enter 7 2 5 Heating Cooling Auto mode Select and press...

Page 19: ...temp 30 70 flash if Real value 9 d06 Gas exhaust temperature 0 C5 125 Real testing value d07 Step of EEV 0 99 N 5 d08 Compressor running frequency 0 99Hz Real testing value d09 Compressor current 0 3...

Page 20: ...Compressor Frequency 18 110 50 Adjustable if P08 1 P10 Opening degree of EEV 0 470 350 Adjustable if P08 1 P11 Fan motor rotate speed 300 1000 500 Adjustable if P08 1 P12 Communication port of modbus...

Page 21: ...P3 0 T1 28 5 last for 30 minutes 1 Then it enters into standby mode for 1 hour It will not restart except turn it on manually 2 After 1 hour the filtration pump will restart for 5 minutes If it tests...

Page 22: ...is normal button is invalid For example 7 2 9 Time setting Timer setting Select and press to enter press again to Timer on Timer offsetting Press to enter and and to select Timer on or Timer off Press...

Page 23: ...g press for 5 seconds press and to set the current local time then confirm the setting by pressing Finally exit by 8 Electrical Wiring 8 1 Model CHP075PX CHP095PX CHP115PX CHP135PX CHP165PX CHP205PX C...

Page 24: ...e located within sight of and readily accessible from the unit This is common practice on commercial and residential heat pumps It prevents remotely energizing unattended equipment and permits turning...

Page 25: ...of sensor is loose 1 Check or change the sensor 2 Re fix the wiring of the sensors Antifreeze protection in Winter PP07 Ambient temperature or water inlet temperature is too low 1 Check the d1 and d3...

Page 26: ...or replace a new low pressure switch EE03 Or 1 The wiring of water flow switch is loose or 1 Check the wiring of water flow switch Water flow failure TS1 ON water flow switch damaged 2 No or Insuffic...

Page 27: ...Check the compressor phase 4 Check the phase sequence connection 5 Check the waterway system and filtration pump 6 Check mains power input Communication failure between controller and main board EE08...

Page 28: ...lumbing system 3 Check if the power is in the normal range 4 Check if the reactor is used correctly IPM module thermal circuit is abnormal EE14 1 Output abnormity of IPM modulethermal circuit 2 Fan mo...

Page 29: ...ade if it is broken 4 Check the screw on driver board Input power failure EE20 The supply voltage fluctuates too much Check whether the voltage is stable Software control exception EE21 1 Compressor r...

Page 30: ...rect EEPROM data 2 Change a new main board The inter chip communication failure on the main control board EE28 Main board failure 1 Stop electricity supply and restart it 2 Change a new main board Rem...

Page 31: ...oling when HP runs under heating mode LED wire controller displays actual water temperature and no error code displays 1 Choose the wrong mode 2 Figures show defects 3 Controller defect 1 Adjust the m...

Page 32: ...30 10 Exploded view 10 1 Model CHP075PX CHP095PX...

Page 33: ...clip 13 Front panel 43 Water outlet temp sensor 14 Display cover 44 Rubber ring on water connection 15 Controller 45 Water flow switch 16 Controller box 46 Sealing ring 17 Service panel 47 Red rubber...

Page 34: ...32 10 2 Model CHP115PX CHP135PX CHP165PX...

Page 35: ...clip 13 Ventilation panel 43 Water outlet temp sensor 14 Front panel 44 Rubber ring on water connection 15 Display cover 45 Water flow switch 16 Controller 46 Sealing ring 17 Controller box 47 Red ru...

Page 36: ...34 10 3 Model CHP205PX CHP255PX...

Page 37: ...anger to filter 14 Controller box 45 4 way valve to exchanger 15 Controller 46 Exchanger temperature sensor clip 16 Display cover 47 Water outlet temp sensor 17 Service panel 48 Rubber ring on water c...

Page 38: ...36 10 4 Model CHP305PX...

Page 39: ...l 47 Exchanger temperature sensor clip 15 Front panel 48 Water outlet temp sensor 16 Controller box 49 Rubber ring on water connection 17 Display cover 50 Water flow switch 18 Controller 51 Sealing ri...

Page 40: ...lumbing system is fully charged with water before the unit is turned on and expected to run again 5 After the unit is prepared and conditioned for the Winter season it is recommended to cover the heat...

Page 41: ...ne s app and several phones app could connect to one heat pump 12 2 Alsavo Pro APP operation 2 1 Firstly please confirm the Parameter P17 1 WIFI function in the controller Parameter Description Scope...

Page 42: ...40...

Page 43: ...hree modes Auto mode cooling or heating for the CHP PX unit Click its icon to switch between modes Auto mode heating cooling 3 Timer setting Click it turns Timer on and off will be activated together...

Page 44: ...42...

Page 45: ...43 4 Parameter checking and setting Click Parameter then enter the password 0757...

Page 46: ...tion 9 0 to 9 0 3 Temperature unit or 4 When you want to reset to factory default setting tips as below pop up 4 Switch running modes In heating or cooling mode there are 3 running modes Silent Smart...

Page 47: ...45...

Page 48: ...he set water temperature on the display changes it will be synched and updated to the APP and thus the HP will follow suit if it has a good and steady connection to the Wi Fi 7 Check device informatio...

Page 49: ...47 NOTE Please also see Further Terms and Conditions on the suppliers websites to be read alongside these Manufacturer s instructions...

Page 50: ......

Page 51: ...A0211MPX02...

Reviews: