19
-
Remark: Logic of filtration pump control
*We do NOT recommend the heat pump is used to control the filtration system.*
Reasons: If ambient temperatures keep the body of water above or at the set temperature, Filtration/pump
will not come on, the ability to filter and/or sanitize that body of water will be lost.
Also, the WARRANTY will not cover "blown" mother boards (PCB`s) due to faulty wiring of water pump OR a
water pump becoming defective also causing damage to the heat pump.
Option 1; P3=0 Filtration pump is related to heat pump operation to start and stop.
Filtration pump starts 60s before compressor, filtration pump start 30s and then the water flow switch detect
flow. Before the heat pump enters into Standby mode, the compressor stops first and after 5 minutes filtration
pump stops.
Mode
Condition
Example
Water pump working logic
Heating
mode
P3=0,
T1≥Tset-0.5
℃
,
last for 30
minutes
P3=0,
T1≥27.5
℃
,
last for 30
minutes
1. Then it enters into
standby mode for 1 hour
(It will not restart except
turn it on manually.)
2. After 1 hour, the filtration pump
will restart for 5 minutes. If the
T1≤27
℃
,the heat pump will start to
work until T1≥27.5
℃
and last for 30
minutes to go into standby
Cooling
mode
P3=0,
T1≤Tset+0.5
℃
,
last for 30
minutes
P3=0,
T1≤28.5
℃
,
last for 30
minutes
1. Then it enters into
standby mode for 1 hour
(It will not restart except
turn it on manually.)
2. After 1 hour, the filtration pump
will restart for 5 minutes. If it tests
T1≥29
℃
,the heat pump will start to
work until T1≤28.5
℃
and last for 30
minutes to go into standby
Option 2; P3=1 Filtration pump is always on, P2=0 the timer function is no active
Under condition P3=1, whenT1≥Tset+1
℃
(T1≥29
℃
)last for 3 minutes, heat pump will be in standby, while
filtration pump is always on.
Under option 2, with activation of the timer; P2=1 to start and stop the filtration pump according the
programming of the P4 (time), P5 (Timer ON) and P6 (Timer OFF)
Condition for the heat pump start, timer ON actives;
When the timer reaches
the set time of TIMER ON
, the filtration pump will start and after 5 minutes the
heat pump start. The heat pump stays in stop if the water in temperature is ≥ Tset+1
℃
,before the TIMER OFF,
the filtration still activated.
Condition to stop the heat pump, timer OFF actives;
Before the TIMER OFF, the heat pump stops and the filtration is still activated. When timer reaches the set
time of the TIMER OFF, the heat pump will stop and after 5 minutes the filtration pump stops.
NOTE:
Tset = Tseting water temperature, for example: Tset = 28
℃
Tseting water temperature in your pool heat
pump
Tset-0.5 = less 0.5
℃
than Tseting temperature, Tset- 0.5 = 28-0.5=27.5
℃
Tset+0.5= more 1
℃
than Tseting temperature, Tset+ 0.5 = 28+0.5=28.5
℃
Summary of Contents for CHP075PX
Page 1: ......
Page 2: ...Please read and understand ALL the instructions before installation and use...
Page 6: ...4 2 Dimension unit mm 2 1 Model CHP075PX CHP095PX...
Page 7: ...5 2 2 Model CHP115PX CHP135PX CHP165PX 2 3 Model CHP205PX CHP255PX...
Page 8: ...6 2 4 Model CHP305PX...
Page 11: ...9 Dry contact timer connection Timer Dry contact pump connection Water pump...
Page 32: ...30 10 Exploded view 10 1 Model CHP075PX CHP095PX...
Page 34: ...32 10 2 Model CHP115PX CHP135PX CHP165PX...
Page 36: ...34 10 3 Model CHP205PX CHP255PX...
Page 38: ...36 10 4 Model CHP305PX...
Page 42: ...40...
Page 44: ...42...
Page 45: ...43 4 Parameter checking and setting Click Parameter then enter the password 0757...
Page 47: ...45...
Page 50: ......
Page 51: ...A0211MPX02...