7.2.7
Parameter setting
Select
and press
to enter, press
and
to choose P0-P18 value and
press
to set.
Note: Long press
for 10s to set P8, P12, P13, P14, P15, P17, P18.
Code
Name
Scope
Defa
ult
Remark
P00 Mandatory defrosting
0-1
0
0: Default normal operation
1: Mandatory defrosting.
P03 Water pump
0-1
0
1:Always running;
0:Depends on the running of compressor
P07 Water temp. calibration
-9~9
0
Default setting: 0
P08 Adjustable for P9-P11
0~1
0
1: Adjustable for P9, P10, P11
0: Not adjustable for P9, P10, P11
P09 Compressor Frequency
18~110
50
Adjustable if P08=1
P10 Opening degree of EEV
0~470
350
Adjustable if P08=1
P11
Fan motor rotate speed
300~1000
500
Adjustable if P08=1
P12
Communication port of
modbus
0~5
0
Only available for HP with modbus
P13
ID NO. of modbus
protocol
1~88
9
Only available for HP with modbus
P14
Restore to factory
settings
0~1
0
0: Default
1: Restore to factory settings
(restore P00, P03, P07, P08, P09, P10, P11
to factory setting)
P15 Model code in modbus
Only available for HP with modbus
P16 Product code
/
/
Depend on the machine
P17 Modules selection
0~1
0
Only available for HP with modbus or wifi
1: Modbus module
0: Wifi module
P18 Mode
0~1
0
1: Heating only
0: Heating/Cooling/Auto mode
Summary of Contents for CHP075PX
Page 1: ......
Page 2: ...Please read and understand ALL the instructions before installation and use...
Page 6: ...4 2 Dimension unit mm 2 1 Model CHP075PX CHP095PX...
Page 7: ...5 2 2 Model CHP115PX CHP135PX CHP165PX 2 3 Model CHP205PX CHP255PX...
Page 8: ...6 2 4 Model CHP305PX...
Page 11: ...9 Dry contact timer connection Timer Dry contact pump connection Water pump...
Page 32: ...30 10 Exploded view 10 1 Model CHP075PX CHP095PX...
Page 34: ...32 10 2 Model CHP115PX CHP135PX CHP165PX...
Page 36: ...34 10 3 Model CHP205PX CHP255PX...
Page 38: ...36 10 4 Model CHP305PX...
Page 42: ...40...
Page 44: ...42...
Page 45: ...43 4 Parameter checking and setting Click Parameter then enter the password 0757...
Page 47: ...45...
Page 50: ......
Page 51: ...A0211MPX02...