Crystal Vision
Trouble shooting
Indigo 4 User Manual R1.7
31
09/08/2012
The following LED status indications may be seen:
LED
Colour
Notes
Front Fan
(upper)
Unlit
Yell/Grn
Red
Quiet mode/Door open
Normal operation
Change the panel fan
PSU Fan
(upper)
Yell/Grn
Red
Normal operation
Change upper PSU fan
PSU 2
Yell/Grn
Red
Normal operation
Change upper PSU
Mains
Input
Unlit
Yell/Grn
Red
No 4th PSU detected
Normal operation
Alarm. Mains Input 1 or 2 missing, Change PSU 4,
check supply, change upper inlet fuse
Upper
Temp
Yell/Grn
Red
Normal operation
UPPER FRAME TOO HOT, Ambient temperature
too high/fan fault
Front Fan
(lower)
Unlit
Yell/Grn
Red
Quiet mode/Door open
Normal operation
Change the panel fan
PSU Fan
(lower)
Yell/Grn
Red
Normal operation
Change lower PSU fan
PSU 3
Unlit
Yell/Grn
Red
No PSU 3 detected
Normal operation
Change PSU 3
PSU 1
Unlit
Yell/Grn
Red
No PSU 1 detected
Normal operation
Change lower PSU 1
Lower
Temp
Yell/Grn
Red
Normal operation
LOWER FRAME TOO HOT, Ambient temperature
too high/fan fault
Comms
Unlit
Flash amber
No external comms being received.
External comms present
If a PSU is not fitted, the corresponding LED will not illuminate. If the front panel is
open, the Front Fan LED will also be unlit.
The Comms LED indicates external communication with the frame. On a passive panel
this will mean communication from the frame or an active control panel. On an active
panel this will be communication with Statesman via an RS422 link or via Ethernet.
The Comms LED flashes slowly at medium intensity if communication has been
established. It will flash at higher intensity when the communication channel is active.
When a fault is cleared, the corresponding LED (if appropriate) will return to normal. The
Indigo REMIND active front panel can also be used to interrogate the status of the front
panel and installed PSUs by pressing Enter when those devices are listed in Device view.
Statesman users will be able to remotely monitor frame temperature and fan speed.