Crystal Vision
VisionWeb
‘
CV_Hwissue’
is the version of the frame hardware entered during manufacture.
‘
CV_HwModLevel’
indicates modifications to the frame hardware.
Configuration / Backup-Restore / Auto restore
Whenever a card’s settings are changed, a backup copy in the Frame Controller Processor
(FCP) is automatically updated. This feature allows, for instance, a faulty card to be replaced
live and its settings automatically transferred to the replacement.
This web page sets the conditions for the restore of the card’s settings from the stored
backup. If enabled, this process happens automatically whenever the frame is powered or
reset, or whenever a card is plugged in live:
VisionWeb Configuration/Backup-Restore/Auto Restore page
The process can be enabled or disabled for each slot in the frame. If the ‘Card ID must match’
box is checked then the restore process will only happen if the card currently in the slot is of
an identical type to the card used to create the backup. If the box is NOT checked, the restore
process will be applied to the card in the slot regardless of type. This will only be valid if the
backup and restore process are for cards of a similar generic group that may have different
card IDs for the various options, but common control and status registers (i.e. TANDEM 310,
320 etc.). If in doubt, check the box. Although Indigo 1 has only six slot positions, the
Configuration/Backup-Restore/Auto restore page shows 24 slots. This is to provide ‘virtual
card’ slots which is one made up of controls from several cards in a frame and allocated a
unique slot number – see section
Virtual Cards
.
The ‘FTP Import/Export’ button opens an index to the ‘backup’ folder showing a list of the
backup files that have so far been created:
Indigo 1 User Manual R1.14
32
27 February 2020