INSTALLATION & OPERATION MANUAL 10272 REV 2 (04/22)
PAGE
17
OF20
Electric Counter Convection Steamer
Adjustment for High Altitude Locations
Adjustment for High Altitude Locations
NOTICE
Contact the factory, the factory representative or local service company to perform maintenance and repairs.
The steamer has been factory set so that when it is ON and in the READY mode, it will maintain water temperature in the
steam generator tank at approximately 205 degrees Fahrenheit (just below water boiling point). However, for high altitude
locations, an authorized servicer must adjust the steamer temperature lower. To adjust:
1. Close the manual drain valve and remove side panel and turn control panel power switch to ON.
2. Open compartment door, and after about 5 minutes, steam will be seen, entering the cooking compartment.
3. Turn thermostat shaft counterclockwise to lower temperature until steam just ceases to enter cooking compartment
and READY light goes on.
4. Replace side panel.
5. Follow TESTING PROCEDURES in this manual.