INSTALLATION & OPERATION MANUAL 10272 REV 2 (04/22)
PAGE
16
OF 20
Electric Counter Convection Steamer
Removal of Scale Deposits (continued)
Maintenance
WARNING
Read and follow instructions on the CLR bottle. Use plastic or rubber gloves to avoid skin contact. If CLR comes in
contact with skin, rinse with clean water.
1. Set the power switch to OFF and drain steam generator by opening the manual drain valve.
2. Delime port (A) is located on left side at the rear of the unit. Close the manual drain valve and unscrew hex plug from
elbow to allow CLR solution to be poured in using a tube and funnel. Pour in 28 ounces of solution into the generator
(pour slowly to avoid spillage). Remove tube and funnel.
3. Screw the hex plug back into the elbow so that it is sealed.
4. Turn power switch to ON and set the timer to OFF.
5. Allow steamer to remain in READY cycle for 1-1/2 hours, then turn power switch OFF and open the manual drain
valve to allow generator to completely empty.
6. FLUSH CYCLE: Close the manual drain valve and turn the power switch ON. When the READY light comes on, turn
power switch to OFF and open the manual drain valve to allow generator to completely empty. Repeat these steps
three times to completely flush generator.
7. Clean exterior and interior. Use a mild solution of soap and water. Rinse with clean cloth. Dry with soft cloth. Leave
compartment door open when not in use.
The steamer is now ready for use. Turn off for overnight shutdown.