INSTALLATION & OPERATION MANUAL 10272 REV 2 (04/22)
PAGE
4
OF 20
Electric Counter Convection Steamer
Service Connections
ELECTRICAL CHARACTERISTICS
COMPARTMENT PAN CAPACITY, WEIGHT AND CLEARANCE
SERVICE CONNECTIONS
– ELECTRICAL CONNECTION: ø 1 1/8” hole for electrical connection. Rating to be as specified on data plate.
– COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 psi (170-345 kPa).
– GENERATOR WATER: 3/8” (10 mm) O.D. tubing at 25-50 psi (170-345 kPa).
– DRAIN: 1” (13 mm) NPT
Model
Pan Depth
Inches
1”
2.5”
4”
6”
Shipping Weight
Minimum Clearance
MM
25
64
102
152
SXN-4M
Total Quantity of Pans
8
4
2
2
155 lbs. [70 kg]
SIDES
BACK
0
0
Terry System Cartridge Changes / Installation
– “2-3 gallons of water MUST be purged at each cartridge change or new installation prior to
water supply being fed to the steamer. Failure to do so can result in component damage within the steamer which is not covered under warranty.
For additional guidance on proper installation, refer to install documentation provided with each Terry System and Replacement Cartridge Set.”
DISCLAIMER
WATER QUALITY STATEMENT
Water is the essential ingredient in steam equipment, water quality is the major factor affecting the performance of your appliance. Crown Steam Group offers a
Comprehensive Water Treatment System which exceeds our minimum water requirements. Proof of installation and proper cartridges replacement is required for
warranty coverage. Water supply to Crown Steam Group steamers must be within these guidelines.
Total dissolved solids.......................Less than 60 PPM
Chlorine
............................
Less than 1.5 PPM
Total alkalinity ........................................
Less than 20 PPM
pH Factor
.........................
6.8 - 7.3
Silica
.......................................................
Less than 13 PPM
Water which does not meet these standards should be treated with the installation of Middleby’s Water Treatment System. Call 919-762-1000 if you have questions
concerning your water meeting these parameters.
*Failure or malfunction of this appliance due to poor water quality is not covered under warranty.
Reference www.crownsteamgroup.com for complete warranty details and instructions.
As continued product improvement is a policy of Crown, specifications are subject to change without notice.
Service Connections
Model
kW
AMPS/PHASE
208V
220V
240V
380V 8.4kW
415V
1 PH
3 PH
1 PH
3 PH
1 PH
3 PH
3 PH
3 PH
SXN-4M
9
48.1
27.8
38.2
22.1
41.7
24.1
12.8
13.9