Page 46
CDi DriveCore Series Operation Manual
Application Examples
Bridge Mono Mode, Low Z (16Ω, 8Ω, or 4Ω)
Audio Architect software settings are shown in
. Typical input/
output wiring is shown in
.
INPUTS:
If using analog inputs, connect to the odd-numbered input
channels (1,3) only. Even-numbered inputs (2,4) are disabled when Bridge
"Wiring Input Connectors" on page 7
for further information on analog input wiring.
If using the BLU link input, it is important to understand that BLU link is a
digital audio bus and cannot be routed through an Ethernet switch or router.
Category 5e or higher cabling must be used for all BLU link connections.
To use the built-in BLU link fault protection, the BLU link output of the last
device on the bus must be connected back to the BLU link input of the first
device. For additional information on making BLU link connections and
using BLU link, see
OUTPUTS:
Connect the speaker across the positive (+) terminals of each channel pair. Do not use the negative (-) terminals of the channel pair when the
pair is being operated in Bridge Mono mode. See
"Wiring Output Connectors" on page 7
for additional information on output wiring. See
"Configuring Amp Wiring & Bridge Mode" on page 13
for information on configuring an output pair for bridge mono operation.
2
1
2
1
2
1
Figure 61:
System wiring in Bridge Mono mode
NOTE:
Always route the input and output wires in separate bundles.
WARNING:
Only connect to networks that remain inside the building.
Figure 60:
Audio Architect amplifier mode settings
Summary of Contents for 2/300