Page 16
CDi DriveCore Series Operation Manual
Configuring the Amp
Configuring Output Modes
From the Output Mode Setup screen (see
), outputs can be configured for Low
Z or High Z operation. By default, the CDi DriveCore amplifiers are configured for Low Z
operation on all outputs.
To configure output mode settings:
1�
From the Home screen, press the
MENU
button.
2�
Select the "Configure Amplifier" option from the menu using the
ENCODER
.
3�
Select the "Output Mode (70V/100V)"
option from the menu.
4�
Use the
ENCODER
to navigate, make selections, and edit settings.
5�
When done, select "Done" at the bottom of the screen.
Available options:
•
LoZ, 70V, 100V
Configures the output for the application type. Select the "LoZ" option for conventional low-impedance (2/4/8Ω) passive speakers, or choose the
appropriate voltage setting if configuring the output for a high-impedance (contsant-voltage) install application.
NOTE:
If a pair of outputs are configured for bridge mono operation, selecting the 70V option will provide 140V and selecting the 100V option will
provide 200V.
"Configuring Amp Wiring & Output
Modes in Audio Architect" on page 36.
Configuring DSP
) you can manually edit crossover, delay, and
limiter settings to optimize the loudspeakers. Note that this screen shows the status of each
DSP module (block). When a module is darkened, it is bypassed. When a module is bright,
it is turned on.
To manually edit DSP settings:
1�
From the Home screen, press the
MENU
button.
2�
Select the "Configure Amplifier" option from the menu using the
ENCODER
.
3�
Select the "Edit DSP"
option from the menu.
4�
Use the
ENCODER
to select the module you wish to edit.
5�
Use the
ENCODER
to navigate, make selections, and edit settings.
6�
When done, select "Done" at the bottom of the screen.
Figure 16:
Output Mode Setup screen
Figure 17:
Edit DSP screen
Summary of Contents for 2/300
Page 91: ......