INSTRUCTION MANUAL

MODEL 4117-14 Block Up/Downconverter

TABLE OF CONTENTS                                           PAGE

Warranty

2

1.0 General

3

1.1  Equipment Description

3

1.2  Technical Characteristics

4

2.0 Installation

6

2.1  Ethernet Interface Installation

7

  

2.1.1  Methods of Connection

 7 

  

2.1.2  Ethernet Configuration

7

         

2.1.3  Web Page M&C

9

  

2.1.4  SNMP Configuration

9

2.2  Up/Downconverter Outline Drawings

12

2.3  Physical Interface

13

2.4  Installation/Operation

14

WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.

All Cross Technologies, Inc. products are warranted against defective materials and 
workmanship for a period of one year after shipment to customer. Cross Technologies, 
Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s 
option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall 
not be liable for any special, indirect, or consequential damages.  This warranty does not 
cover parts or equipment which have been subject to misuse, negligence, or accident by the 
customer during use. All shipping costs for warranty repairs will be prepaid by the 
customer.  There are not other warranties, express or implied, except as stated herein.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005  •  FAX (770) 886-7964  •  Toll Free 888-900-5588

WEB www.crosstechnologies.com  •  E-MAIL [email protected]

4117-14 Manual, Rev. J

 

             Page 2

    

                     03/27/17  

Summary of Contents for 4117-14

Page 1: ...without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment s...

Page 2: ...period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or en...

Page 3: ...ed temperature ranges They are designed to be located out in the elements water sleet snow etc but they are not designed to be submerged under water If an extended temperature range is required there...

Page 4: ...60 dB Mute 0 dBm out 15 to 0 dBm Output Level Range 0 2 to 0 4 GHz Frequency Output Characteristics UHF L Input Characteristics UHF L 1 2 1 4 GHz Frequency GHz 50 14 dB Impedance Return Loss 50 14 dB...

Page 5: ...nnector RJF6G Cable interface Standard RJ45 AC Input Connector Clipper Series CL1M1102 Mating Cable Connector CL1F1101 Unless otherwise specified the mating connector is provided preassembled onto a s...

Page 6: ...Figure 2 5 for mounting dimensions Figure 3 0 Model 4117 14 Up Downconverter Front Panel 2 0 1 Connection to AC Input Power The 4117 14 utilizes a pre assembled AC power input cable as described below...

Page 7: ...ormal RJ 45 cable Use any PC on the LAN to connect to the 4117 14 2 1 2 Ethernet Configuration Each 4117 14 must be configured with an appropriate IP address Netmask and Gateway assigned by your netwo...

Page 8: ...nager click on Network to display the Network Settings screen Enter the IP address Subnet mask and Gateway address with delimiter dots example 192 168 192 47 Click apply settings in the left frame to...

Page 9: ...uires a Telnet connection to port 9999 The following instructions explain how to establish such a Telnet connection using Windows XP s Hyper Terminal utility Start the Hyper Terminal application and s...

Page 10: ...SNMP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of...

Page 11: ...TE Planning Ethernet Access It is recommended that IP knowledgeable customer personnel be consulted as a resource in the installation and use of the Ethernet access features of the Cross Technologies...

Page 12: ...100 240 10 VAC 47 63 Hz Weatherized CL1F1101 Connector See Table 1 0 Fuse 1 25 X 25 1 5 amp slow blow Type T PRESSURE RELEASE VALVE 10MHz OUTPUT SMA Connector 50 Loop through 10MHz INPUT SMA Connecto...

Page 13: ...18S connector The Ethernet signals connect via a standard RJ45 connector Part RJF6G Monitor and Control Connector Monito Monitor and Control Connector Pinout Conne Connector part number MS3112E14 18S...

Page 14: ...l 10 MHz ref AUTO for internal 10 MHz ref UNLESS an external 10 MHz 2 to 8 dBm signal is connected to J3 or EXT for external 10 MHz 2 to 8 dBm ref that is inserted at J3 11 Check that a 10 MHz signal...

Page 15: ...S INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed In USA 4117 14 Manual Rev J...

Reviews: