2.3 Physical Interface
All 411x units provide a RS232/RS422/RS485 interface port and a 10/100 Base-T Ethernet port. Both ports are
available when the unit is installed and powered up. Commands may be sent to either port at any time and they
will be processed in the order that they are received. The RS232/RS422/RS485 signals connect via an 18-pin,
MS3112E14-18S connector. The Ethernet signals connect via a standard RJ45 connector, Part #RJF6G.
Monitor and Control Connector
Monito
Monitor and Control Connector Pinout
Conne
Connector part number MS3112E14-18S
Mating
Mating Cable Connector part number MS3116F14-18P
Pin Signal Description
A
Chassis Ground
N
Summary Alarm Normally Closed
P
Summary Alarm Common
R
Summary Alarm Normally Open
E
RS422/RS485 Data Out-
F
Signal Ground
C
RS422/RS485 Data In-
D
RS422/RS485 Data Out+, RS232 Data Out
B
RS422/RS485 Data In+, RS232 Data In
4117-14 Manual, Rev. J
Page 13