FMUX/S-4E1-E2 Multiplexer
1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567
1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567
Copyright © 2007 Cronyx
34
•
'Error rate: ...'
– error rate in the received data, 10
-1
to 10
-8
. If testing is not enabled,
then this field shows the 'Testing disabled' message; if the test pattern has not been
detected in the received data, the 'Test pattern not detected' message is output.
Error rate measurement device modes are not saved in the nonvolatile memory.
4.8. 'Configure' menu
The '
Configure
' menu allows to select multiplexer operating modes:
Configure
Mode: Normal; Sensor=Open
Link: Ok
1. Ports usage...
2. E2 sensitivity: 0...-2.8 dB (cable 0...170 meters)
3. SNMP...
4. Sensor input: Alarm on closed
5. Factory settings
6. Save parameters
7. Restore parameters
Command: _
After setting the parameters, you should save them in the non-volatile memory (NVRAM)
using the '
Save parameters
' command. If the current parameters have been set unsuc-
cessfully, the saved configuration may be restored using the '
Restore parameters
' com-
mand. If required, all settings may be restored to a known initial state using the '
Factory
settings
' menu item.