Page 1: ...KAIWEETS True RMS 10000 Counts Smart Digital Multimeter m User Manual Contact us support kaiweets com CRHSFEET omn_ AXMIN avereL 1 A iy oo 6H80 TRUE RS MKQHZ BmAVFCE s C 10000 Counts A macoM ieuT...
Page 2: ...ot measure voltages higher than the rated value between terminals or between terminals and ground Check that the meter is working properly by measuring a known voltage and do not use it again if it is...
Page 3: ...sks and flame retardant clothing to prevent injury from electric shock when dangerous live conductors are exposed When the low voltage indicator appears replace the battery promptly to prevent measure...
Page 4: ...a Charge Jack b NCV Sensor Power Button d Alarm Indication Light LCD Display colorful f Function Buttons g AJack h mA Jack i COM Jack J INPUT Jack k Flashlight...
Page 5: ...directives Suitable for testing circuits directly connected to power points sockets and power installations in buildings CATIl ave D similarities of low voltage power installations caTm Suitable for m...
Page 6: ...return to the SMART Auto mode In SMART Mode the AUTO signal will display on the screen and the top left corner will display SMART Press button to select functions Press button more than 2 seconds to...
Page 7: ...temperature NCV Live test In maximum minimum measurement the meter will enter the manual range mode HOLD REL Press once to turn on off data holding Press for about 2 seconds to turn on off Relative Va...
Page 8: ...ttery AC Alternating DC Direct s Double Insulat Curent Curent oouble nvites P piode Test 2 carn QQ Resistance Test Capacitance Live Wire Non contact Ie Test Detection Nev Voltage Detection Fuse Damage...
Page 9: ...users to insert the right test leads to the right jack b Input terminal for measuring ac and dc current to 10A c Input terminal for measuring ac and dc current to 630mA d Common return terminal for al...
Page 10: ...voltage resistance continuity it selects the range with the best resolution automatically Turn on Ready to use 1 Long press the button for about 2 seconds to turn on the meter Auka will be displayed o...
Page 11: ...ce value is less than 500Q the meter will beep and the indicator will light up 3 The minimum measurable voltage in SMART mode is 0 5V AC 0 8V DC MANUAL Measurement Mode The Meter defaults to SMART mod...
Page 12: ...creen 3 Do not use the AC voltage test function to test DC voltage and vice versa 4 Do not measure voltage exceeding 1000V DC or 750V AC to avoid damage to the meter Resistance measurement 1 Press A9...
Page 13: ...sounds 6 Read the measurement results from the display NOTE If the resistance of the circuit or resistor under test is less than 500 and the circuit is on position the buzzer will beep and an indicat...
Page 14: ...ituations When the meter probe is properly connected 1 Forward Bias When the meter probe is incorrectly connected l v Reverse Bias Bad Diode There will be two situstions 5 When the meter probe is prop...
Page 15: ...pacitor under test 4 Read the measurement results from the display NOTE 1 If the measured value is significantly different from the value marked on the capacitor the capacitor is damaged 2 Before meas...
Page 16: ...erwise the ambient temperature is displayed 6 Read the results from the display NOTE 1 When measuring AC voltage the frequency will be displayed 2 When measuring DC voltage the ambient temperature wil...
Page 17: ...the K Type thermocouple to the object being measured The reading may take few seconds to be stable NOTE When the K Type thermocouple does not in contact with the object under test it will read the am...
Page 18: ...sert the red probe into the INPUT jack and remove the black probe 3 Touch the object under test with the red test lead point NOTE 1 When the indicator light lights up that means the measured position...
Page 19: ...d on the screen and the indicator light will turn red when the test leads are connected incorrectly please insert the red test lead into A jack 3 The meter will turn on the current testing function wh...
Page 20: ...ayed on the screen and the indicator light will turn red when the test leads are connected incorrectly please insert the red test lead into mA jack 3 The meter will turn on the current testing functio...
Page 21: ...ignal will be displayed on the screen when the fuses are blown current testing function is not working then please change the fuses 1 Remove test leads from the Meter before opening the case 2 Remove...
Page 22: ...sh 5 times Low Battery Damaged Fuse Indication 3 Indication Overload Environmental OL Displayed CAT IV 600V CAT IIl 1000V Indication conditions Polarity Automatically mA F630mA 250V fuse Fuse protecti...
Page 23: ...o 80 Accuracy of Reading Counts DC voltage AC voltage Range Resolution Accuracy Range Resolution Accuracy 99 99mV 0 01mV 99 99mV 0 01mvV 999 9mV 0 1mV 999 9mV 0 1mV 0 8 3 9 999V 0 001V 0 5 3 9 999v 0...
Page 24: ...0 01nF 600 0mA 0 1mA 9nF 1nF i o 999 50 O 4 0 3 9 999A 0 001A 1 2 3 9 999uF 0 001pF Overload protection 99 99uF 0 014F mA F630mA 250V fuse 999 9uF 0 1uF 10A F10A 250V fuse 9 999mF 0 001mF 5 0 5 Frequ...
Page 25: ...age about 3 3V on Resistance 50Q buzzer will sound and the indicator light will be on Resistance Range Resolution Accuracy 999 90 0 1Q 9 999KQ 0 001 KQ 99 99 KQ 0 01V KQ 1 0 5 999 9 KQ 0 1V KQ 9 999MQ...
Page 26: ...0 01Hz 3c 1 09 999 9Hz 0 1Hz c 0C 400C 1 0 or 9 999KHz 0 001KHz 1 0 3 2 99 99kHz 0 01kHz 400C 1000C 2 0 999 9kHz 0 1kH 5 09 iz iz 40 F 32 F 15 0 or 9 999MHz 0 001MHz 6F 99 0 9 1 0 T1 0 ort 1 0 99 0 0...