English
25
6.3 Connection to mains power
The unit can operate with voltage from 90 to 250Vac and with frequency of 50 and 60Hz.
For the connection use main cable in the side of the rear boxl of the fixture and connect as shown below.
EMERALD
is fitted with butt connectors and heat shrink tube which allow to perform
IP67
connections.
To make the connection follow these instructions.
A.
Open the bag with label “POWER SUPPLY”.
You will find inside a piece of heat shrink tube and 4 butt connectors.
B.
Insert the tube
“5”
onto the power supply cable
“6”
on the
side of the rear box of the unit.
Warning!
• Before connecting the unit, verify that power supplies features are compatible with the unit features.
• The unit must never be installed if not grounded electrically.
• It is suggested to use a magnetothermic switch along the power supply line, as prescribed by in force rules.
• The unit must not be powered up through a dimmer power device.
• Wiring and connection actions are to be performed by a qualified staff.
5
6
Live
Ground
Neutral
Brown
Yellow Green
Blue
Main supply