English
31
Emerald
can operate without DMX signal (in AUTOMATIC mode) and can be set so that a single MASTER unit will
command a series of SLAVE units. This function is particularly useful when more units are desired to execute the
same programme in synchrony.
The following picture shows an example of a Master-Slave layout.
9.1 AUTOMATIC configuration
To activate the AUTOMATIC mode, press the “MENU” button up to visualize “ADR”. Through the “UP” and “DOWN”
keys select “AUT”. Press “ENTER” to confirm.
Through the “UP” and “DOWN” keys select “ACT”. Through the “UP” and “DOWN” keys select “ON” or “OFF” to
activate or deactivate the AUTOMATIC mode. Press “ENTER” to confirm.
It is possible to adjust the length of time of the scenes of the programmes.
Through the “UP” and “DOWN” keys select “TI” and press “ENTER” to confirm. Through the “UP” and “DOWN” keys
select the length of time desired (5-10-20-40 seconds) and press “ENTER” to confirm.
Now, through the “UP” and “DOWN” keys, it is possible to scroll the 8 preset programmes (P1-P8). Once positioned
onto the desired programme, press “ENTER” to confirm. By the keys “UP”and “DOWN” select “ON” or “OFF”. It is
possible to activate or disactivate the programme. Press ENTER to confirm.
Now the unit is in AUTOMATIC mode and the diplay will keep reading “AUT”.
To exit from the AUTOMATIC mode, press the “MENU” button, select “ACT” and press “ENTER” to confirm.
Select “OFF” to deactivate the AUTOMATIC mode. Press ENTER to confirm.
9.0 Master-Slave and Automatic function
Warning!
It is possible to select more programmes which will be executed in sequence.
If MASTER-SLAVE mode is being used, the fixture cannot be controlled by a DMX control device
and no other DMX control device must be present along the line!!
If the DMX connectors in the rear panel of the unit are not used,
they are to be connected one with each other, in order to preserve the IP65 protection rate.
MASTER
SLAVE 1
SLAVE N
IN
OUT
IN
OUT
SLAVE 2
IN
OUT
OUT
Terminal
plug IP65
(R=120
ƺ
not
included!)