C.
Make the connection to the network by using the butt
connectors
“7”
, pressing them with a proper tool
“8”
.
D.
Warm up the tube by using a heater for heat shrink tubes
“9”
till the complete shrinkage.
The connection so obtained features an
IP67
protection rate.
6.4 Connection to DMX signal
The DMX signal is to be connected by using a shielded cable designed for devices RS-485.
The signal cable must be connected according to the following table:
GND = Hose
DATA - = Black
DATA + = Red
EMERALD
is fitted with butt connectors and heat shrink tube which allow to perform
IP67
connections.
To make the connection follow these instructions.
Warning!
All data wires must be isolated one from another and from the shield.
The GND of the DMX signal is not to be connected to the electric ground of the unit.
Insert a terminal plug with a 120 Ω resistor connected to DATA- and DATA+ in the last unit.
7
8
9