Wiring
When wiring the device, consider the following:
•
Use Crestron Certified Wire.
•
Use Crestron power supplies for Crestron equipment.
•
Provide sufficient power to the system.
CAUTION:
Insufficient power can lead to unpredictable results or damage
to the equipment. Use the Crestron Power Calculator to help calculate how
much power is needed for the system (
For more details, refer to “Check Wiring” on page 13.
Mounting Options
The IDOC-PAD-DSWC installs simply and cleanly into existing or newly
constructed walls, with a choice of a pre-construction or post-construction mounting
option. The IDOC-PAD-DSWC is supplied with four screws and clips for post-
construction installation. For a pre-construction installation, use the
PMK-IDOC-PAD-DSW Pre-Construction Wall Mount Kit (sold separately).
NOTE:
Pre-construction refers to framed walls prior to hanging drywall.
Post-construction refers to framed walls with drywall hung.
If the PMK-IDOC-PAD-DSW is to be used and an IDOC-PAD-DSWC is not
available, the installer can either leave the hole in the mounting surface open (if
permitted by local building codes) or attach the cover plate supplied with the
mounting kit.
Installation
Physical installation of the IDOC-PAD-DSWC without a mounting option includes
mounting the unit to the wall and installing the included faceplate. The only tools
required for the procedures presented here are masking tape (or equivalent), a level, a
gypsum board saw (or equivalent), and a #2 Phillips tip screwdriver. The following
procedures are based on the use of the supplied screws and clips for post-
construction installation.
Prepare the Installation Area
The IDOC-PAD-DSWC is designed to be mounted in a wall or lectern. Two overlay
cutout templates (4513896) are supplied. One is in the shape of the required opening;
the other is similar to a frame, with the inner area of the frame the shape of the
required opening. (Refer to the illustrations on pages 6 and 7.) Use the template that
is most convenient.
Operations & Installation Guide – DOC. 7084A
In-Wall Docking Station for iPad
®
: IDOC-PAD-DSWC
•
5
Summary of Contents for IDOC-PAD-DSWC
Page 4: ......