In-Wall Docking Station for iPad
®
Crestron
IDOC-PAD-DSWC
Make sure the cable length value is less than the value calculated on the right side of
the equation. For example, a Cresnet run using 18 AWG Crestron Certified Wire and
drawing 20 watts should not have a length of run more than 333 feet (101 meters). If
Cresnet HP is used for the same run, its length could extend to 1250 feet (381
meters).
NOTE:
All Crestron certified Cresnet wiring must consist of two twisted pairs. One
twisted pair is the +24V conductor and the GND conductor and the other twisted pair
is the Y conductor and the Z conductor.
Strip and Tin Wire
When daisy chaining Cresnet units, strip the ends of the wires carefully to avoid
nicking the conductors. Twist together the ends of the wires that share a pin on the
network connector and tin the twisted connection. Apply solder only to the ends of
the twisted wires. Avoid tinning too far up the wires or the end becomes brittle.
Insert the tinned connection into the Cresnet connector and tighten the retaining
screw. Repeat the procedure for the other three conductors.
Reference Documents
The latest version of all documents mentioned within the guide can be obtained from
the Crestron Web site (
). This link will provide a list of
product manuals arranged in alphabetical order by model number.
Related Reference Document
DOCUMENT TITLE
PMK-IDOC-PAD-DSW Pre-Construction Wall Mount Kit
IDOC-PAD-DSW-*-S Conversion Kit
Further Inquiries
If you cannot locate specific information or have questions after reviewing this
guide, please take advantage of Crestron's award winning customer service team by
calling Crestron at 1-888-CRESTRON [1-888-273-7876]. For assistance in your
region, please refer to the Crestron Web site (
) for a listing of
Crestron worldwide offices.
You can also log onto the online help section of the Crestron Web site
(
) to ask questions about Crestron products. First-time
users will need to establish a user account to fully benefit from all available features.
Future Updates
As Crestron improves functions, adds new features and extends the capabilities of
the IDOC-PAD-DSWC, additional information may be made available as manual
updates. These updates are solely electronic and serve as intermediary supplements
prior to the release of a complete technical documentation revision.
Check the Crestron Web site periodically for manual update availability and its
relevance. Updates are identified as an “Addendum” in the Download column.