Crestron IDOC-PAD-DSWC Operations & Installation Manual Download Page 2

 

 

This document was prepared and written by the Technical Documentation department at: 

 

 

Crestron Electronics, Inc. 

15 Volvo Drive 

Rockleigh, NJ 07647 

1-888-CRESTRON 

 
 
 

Regulatory Compliance

Federal Communications Commission (FCC) Compliance Statement

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Industry Canada (IC) Compliance Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions:
(1) This device may not cause harmful interference and (2) this device must accept any interference received, 
including interference that may cause undesired operation.

CAUTION:

Changes or modifications not expressly approved by the manufacturer responsible for compliance 

could void the user’s authority to operate the equipment. 

NOTE:

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy 
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:

Reorient or relocate the receiving antenna

Increase the separation between the equipment and receiver

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected

Consult the dealer or an experienced radio/TV technician for help

As of the date of manufacture, the IDOC-PAD-DSWC and IDOC-PAD2-DSWC have been tested and found to 
comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance 
Labelling.

 
 
 

Crestron, the Crestron logo, and Crestron Mobile Pro G are trademarks or registered trademarks of Crestron Electronics, Inc. in 

the United States and other countries. Apple and iPad are either trademarks or registered trademarks of Apple, Inc. in the United 

States and/or other countries. Other trademarks and trade names may be used in this document to refer to either the entities 

claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. 

©2011 Crestron Electronics, Inc. 

 

 

Summary of Contents for IDOC-PAD-DSWC

Page 1: ...Crestron IDOC PAD DSWC and IDOC PAD2 DSWC In WallDockingStationforiPad andiPad2 Operations Installation Guide ...

Page 2: ...ith the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following...

Page 3: ...k Wiring 5 Mounting Options 5 Installation 5 Docking Station Removal 9 Hardware Hookup 9 Operation 11 iPad Sleeve 11 Insert the iPad 11 Remove the iPad 12 Problem Solving 13 Troubleshooting 13 Check Network Wiring 13 Reference Documents 14 Further Inquiries 14 Future Updates 14 Return and Warranty Policies 15 Merchandise Returns Repair Service 15 CRESTRON Limited Warranty 15 Operations Installatio...

Page 4: ......

Page 5: ...use with the original iPad while the IDOC PAD2 DSWC is designed for use with the iPad 2 A conversion kit IDOC PAD DSW S CONVERSION KIT is available to allow the IDOC PAD DSWC to be used with an iPad 2 For instructions on installing the conversion kit refer to the latest version of the IDOC PAD DSW S CONVERSION KIT Installation Guide Doc 7215 which is available from the Crestron Web site www crestr...

Page 6: ... PAD DSWC Specifications SPECIFICATION DETAILS Power Requirements Cresnet Power Usage 15 Watts 0 63 Amps 24 Volts DC May be powered via Cresnet or power pack sold separately Environmental Temperature Humidity 32º to 95ºF 0º to 55ºC 10 to 90 RH non condensing Enclosure Construction Faceplate Metal flush mountable post construction mounting clips included additional mounting accessories sold separat...

Page 7: ...ctions available on your IDOC PAD DSWC IDOC PAD DSWC Physical View IDOC PAD DSWC Overall Dimensions Front and Side Views with Faceplate mounting clips not shown 1 11 29 in 287 mm 9 54 in 243 mm 0 24 in 7 mm 8 61 in 219 mm 2 68 in 68 mm Operations Installation Guide DOC 7084A In Wall Docking Station for iPad IDOC PAD DSWC 3 ...

Page 8: ...Indicators CONNECTORS CONTROLS INDICATORS DESCRIPTION 1 Dock Connection 1 Multi pin connector for connection of iPad 2 POWER INPUT 24 VDC 1 2 pin 3 5 mm detachable terminal block 24 Volt DC power input Wire Size 18 AWG maximum An interface connectors for POWER INPUT 24 VDC port is provided with the unit 4 In Wall Docking Station for iPad IDOC PAD DSWC Operations Installation Guide DOC 7084A ...

Page 9: ... framed walls with drywall hung If the PMK IDOC PAD DSW is to be used and an IDOC PAD DSWC is not available the installer can either leave the hole in the mounting surface open if permitted by local building codes or attach the cover plate supplied with the mounting kit Installation Physical installation of the IDOC PAD DSWC without a mounting option includes mounting the unit to the wall and inst...

Page 10: ...4 Screw 04 40 x 2 Pan Head 2018793 4 The 04 40 x 2 screws are for use with IDOC PAD DSWC mounting kits such as the PMK IDOC PAD DSW sold separately NOTE The following drawings are not to scale Do not attempt to use them to prepare the hole in the mounting surface IDOC PAD DSWC Cutout Dimensions 4513896 1 of 2 1 7 8 48 mm 2 51 mm 2 1 3 1 6 71 mm 3 16 5 mm 10 9 16 268 mm 8 9 16 217 mm 6 In Wall Dock...

Page 11: ... PAD DSWC requires 10 inches 254 mm of clearance on the right side to allow the iPad to be removed from the dock 2 Make a small hole near the middle of the designated site and verify that the location is suitable 3 Using masking tape or equivalent fasten the template to the wall verify that the template is level and trace the opening shape on the wall 4 Remove the template and then cut out and rem...

Page 12: ...ounting clip b Thread the screws through the smaller hole in the mounting clips and tighten the screws only enough that the mounting clips are brought flush with the rear of the docking station s flange Do not compress the mounting clips at this time Attaching the Screws and Mounting Clips Thread Screws Through Clips At This End Mounting Clips Mounting Screws 4 6 AB X 2 1 2 2014276 2 Using the sup...

Page 13: ...t it off 3 Loosen and remove the screws that secure docking station to the mounting option in use NOTE If the mounting clips were used make sure that the screws stay attached to their mounting clips 4 Using equal pressure carefully remove the docking station from the opening If necessary secure and label the attached power cable before disconnecting it from the back of the docking station Hardware...

Page 14: ...ng connections to the IDOC PAD DSWC use Crestron power supplies for Crestron equipment Hardware Connections for the IDOC PAD DSWC Rear View POWER INPUT From 24 VDC power source 10 In Wall Docking Station for iPad IDOC PAD DSWC Operations Installation Guide DOC 7084A ...

Page 15: ...position to the closed position by pushing the bottom right corner of the sleeve Open and or Close Sleeve PUSH HERE TO CLOSE OR OPEN Insert the iPad To insert the iPad sold separately into the dock 1 Hold the iPad horizontally with the HOME button on the left and slide it into the dock until the iPad connects with the dock connector Slide the iPad into the Sleeve Operations Installation Guide DOC ...

Page 16: ...from the dock 1 Push in the bottom right of the sleeve to make the sleeve pop out of the wall 2 Hold the right side of the iPad and pull it out of the sleeve Remove the iPad from the Sleeve 3 If desired push in the bottom right of the sleeve to make the sleeve flush with the wall 12 In Wall Docking Station for iPad IDOC PAD DSWC Operations Installation Guide DOC 7084A ...

Page 17: ...ron warranty CAUTION Provide sufficient power to the system Insufficient power can lead to unpredictable results or damage to the equipment Use the Crestron Power Calculator to help calculate how much power is needed for the system www crestron com calculators When calculating the length of wire for a particular Cresnet run the wire gauge and the Cresnet power usage of each network unit to be conn...

Page 18: ...te www crestron com manuals This link will provide a list of product manuals arranged in alphabetical order by model number Related Reference Document DOCUMENT TITLE PMK IDOC PAD DSW Pre Construction Wall Mount Kit IDOC PAD DSW S Conversion Kit Further Inquiries If you cannot locate specific information or have questions after reviewing this guide please take advantage of Crestron s award winning ...

Page 19: ...lt heads and power supplies are covered for a period of one 1 year touchscreen display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shal...

Page 20: ...ron Electronics Inc Operations Installation Guide DOC 7084A 15 Volvo Drive Rockleigh NJ 07647 2030457 Tel 888 CRESTRON 05 11 Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Reviews: