173
3. - program.
Archimedes
II
computer offers two
computing pro-
grams; for air ( program) and for nitrox mixtures or
EAN (Enriched Air Nitrox) dives. Archimedes
II
allows for use
with up to two different nitrox mixtures during the same dive.
NOTE:
Archimedes
II
computer is set at the factory on
program, with the primary mixture’s (Mix 1) O2
value on 21% and PO2 on 1.4. The second mixture (Mix
2) is set at the factory off. Each manual variation of the
manufacturer’s values relating to Air program will start
Archimedes
II
Nitrox computation program.
3.1. - AIR DIVE.
Archimedes
II
computer starts automatically the "Dive" pro-
gram at a depth superior to (ft. 5). During a curve dive the dis-
play will show the following information (picture 10):
1
current depth value, in meters (m) or feet (ft.)
2 no decompression time still available is shown by the
“NDL” - (No Decompression Limit) icon
3 maximum depth reached during the dive
displayed in meters (m) or in feet (ft.), shown by the
“MAX” icon
4 time spent diving, shown by the "DIVE T" icon
indicator of segmented surfacing speed
6 graph of nitrogen amount absorbed during the dive
7 graph representing CNS O2 toxicity level (see chapter
3.3.4)
8 Automatic indicator of altitude level
9
Icon of maximum depth alarm (if switched ON – see 2.5.1)
10 indicator of Nitrox mixture(s) dive
11 MIX1 or MIX2 icons identifies which Nitrox mixture is being
considered by the computer to make its computations
12 ( ) and ( ) icons, that is “Info” (button A) and back-illu-
mination (button C).
Further important information are obtained by keeping pres-
sed button A (
) during the dive, that is (picture 11):
1
current PO2;
2
oxygen percentage of the selected mixture (Air if FO2=21%);
3
maximum depth reached during the dive, in meters (m) or
feet (ft.);
4
current temperature, expressed in °C or °F
The UFDS display show ( ).
NOTE:
When the computer is used for air dives, it is not
necessary to carry out any FO2 change or setting before
the following dive.
During your diving activity, light condition may not allow easy
reading of the display, therefore, it is possible to switch on its
back-illumination by depressing button C ( ). The display’s
back-illumination will last about 5 seconds and may be repea-
ted any time you want. The battery consumption is minimal
when the back-illumination is activated.
Related topics:
• 2.3.
– Dive parameters setting
• 3.4.1.
– Ascent rate.
• 3.3.3. - Mixture changing by diving
• 3.3.4
- CNS toxicity display.
• 3.3.5. - PO2 alarm.
ENGLISH
5
Archimede II 2006 3-11-2006 10:17 Pagina 173
Summary of Contents for Archimede II
Page 1: ...Manuale d istruzione Manuale d istruzione ITALIANO Archimede II 2006 3 11 2006 10 15 Pagina 1...
Page 2: ...Archimede II 2006 3 11 2006 10 15 Pagina 2...
Page 38: ...Archimede II 2006 3 11 2006 10 15 Pagina 38...
Page 79: ...Gebrauchsanweisung Gebrauchsanweisung DEUTSCH Archimede II 2006 3 11 2006 10 16 Pagina 79...
Page 94: ...3 W hrend des Tauchgangs 3 W hrend des Tauchgangs Archimede II 2006 3 11 2006 10 16 Pagina 94...
Page 118: ...118 BIANCA Archimede II 2006 3 11 2006 10 16 Pagina 118...
Page 134: ...3 En inmersi n 3 En inmersi n Archimede II 2006 3 11 2006 10 16 Pagina 134...
Page 159: ...User s Manual User s Manual ENGLISH Archimede II 2006 3 11 2006 10 17 Pagina 159...
Page 172: ...3 While diving 3 While diving Foto Ghisotti Archimede II 2006 3 11 2006 10 17 Pagina 172...
Page 194: ...194 Archimede II 2006 3 11 2006 10 17 Pagina 194...
Page 195: ...195 Archimede II 2006 3 11 2006 10 17 Pagina 195...
Page 196: ...196 Archimede II 2006 3 11 2006 10 17 Pagina 196...
Page 197: ...197 Archimede II 2006 3 11 2006 10 17 Pagina 197...
Page 198: ...Archimede II 2006 3 11 2006 10 17 Pagina 198...
Page 199: ...Archimede II 2006 3 11 2006 10 17 Pagina 199...