167
IIt is recommended that before diving at altitude, wait at least
three hours after arriving at your diving destination. This will
allow a partial release of the residual nitrogen from the body.
The atmospheric pressure at higher altitudes is lower than at
sea level. Therefore, the diver has additional nitrogen in his
body than at the lower altitudes. The excess is gradually
released and the balance re-established within a couple of
days. At this point it is important to check:
The low battery indicator. It should not be on or flashing (pic-
ture 2 a-b).
The computer display is operating. All liquid crystal segments
should be displaying.
WARNING:
Should the display show the symbol of a low
battery (picture 2 a-b), the computer must NOT be used.
Additionally, should it display during a dive, the diver must
immediately surface. A battery replacement is required as
outlined in chapter 5.
2.3. - PARAMETERS SETTING.
In order to set the dive’s parameters, you must depress the
central button B (Mode), and the icon relating to the
program
you want to use will be shown (picture.3): , for air dives
( ) or Nitrox, mixture(s), or if you want to use
the depth meter /timer program.
NOTE:
Archimedes
II
computer is preset on pro-
gram.
2.3.1. - DIVE program parameters setting.
NOTE:
Archimedes
II
computer is preset on pro-
gram.
This is the basic program with which the Archimedes
II
is set.
It is possible to modify its parameters by repeatedly depres-
sing button A ( ), which allows you to select, in the following
order, the dive’s parameters relating to:
PO2 Mix 1 -> FO2 Mix 1 -> PO2 Mix 2 -> FO2 Mix 2
-> Safety Factor -> Max Depth -> OFF/ON -> DIVE
that is:
• PO2 Mix 1 is the partial pressure of the former of the two
Nitrox mixtures, so that Archimedes
II
can make its decom-
pression computations. The diver can set it on values bet-
ween 1.0 bar (included) and 1.6 bar (included), by variations
of 0.1 bar, obtained at each pressure of button C ( );
NOTE:
By varying of max PO2 setting (picture 3), the com-
puter also indicates the maximum depth (MAX) that may be
reached with that mixture.
WARNING:
Both mixtures’ PO2 factory set on a basic value
(default) of 1.4 bar, both for air dives and for Nitrox mixture
dives. The diver is then following the most conservative
values recommended for sport dives. Different PO2 values
may be set as shown in chapter 3.3. The set value will be
memorized in the computer until the diver chooses another
setting.
i
ENGLISH
Archimede II 2006 3-11-2006 10:17 Pagina 167
Summary of Contents for Archimede II
Page 1: ...Manuale d istruzione Manuale d istruzione ITALIANO Archimede II 2006 3 11 2006 10 15 Pagina 1...
Page 2: ...Archimede II 2006 3 11 2006 10 15 Pagina 2...
Page 38: ...Archimede II 2006 3 11 2006 10 15 Pagina 38...
Page 79: ...Gebrauchsanweisung Gebrauchsanweisung DEUTSCH Archimede II 2006 3 11 2006 10 16 Pagina 79...
Page 94: ...3 W hrend des Tauchgangs 3 W hrend des Tauchgangs Archimede II 2006 3 11 2006 10 16 Pagina 94...
Page 118: ...118 BIANCA Archimede II 2006 3 11 2006 10 16 Pagina 118...
Page 134: ...3 En inmersi n 3 En inmersi n Archimede II 2006 3 11 2006 10 16 Pagina 134...
Page 159: ...User s Manual User s Manual ENGLISH Archimede II 2006 3 11 2006 10 17 Pagina 159...
Page 172: ...3 While diving 3 While diving Foto Ghisotti Archimede II 2006 3 11 2006 10 17 Pagina 172...
Page 194: ...194 Archimede II 2006 3 11 2006 10 17 Pagina 194...
Page 195: ...195 Archimede II 2006 3 11 2006 10 17 Pagina 195...
Page 196: ...196 Archimede II 2006 3 11 2006 10 17 Pagina 196...
Page 197: ...197 Archimede II 2006 3 11 2006 10 17 Pagina 197...
Page 198: ...Archimede II 2006 3 11 2006 10 17 Pagina 198...
Page 199: ...Archimede II 2006 3 11 2006 10 17 Pagina 199...