3.5.1. – Omitted Decompression stage alarm.
If the decompression stage is missed by surfacing above the
depth given by the computer, an alarm will sound and the dis-
play will flash until the diver descends back to the proper
depth (ceiling) or below it (picture 21).
The computer allows a maximum time of 3 minutes to cor-
rect this dangerous situation; during this time, the alarm will
continuing sounding. In the event that the diver does not
descend to the proper depth (after 3 minuets) the computer
display “Error” program and won’t be usable for the next 48
hours. The only functions working will be Logbook/Profile and
History.
m
DANGER:
Should this happen, you must not dive for the
next 48 hours.
In the event that you feel any symptoms of decompression
sickness or air embolism, you should contact emergency
medical services as available in your area. Additionally, DAN
(Divers Alert Network) or your local hyperbaric chamber cen-
ter should be contacted.
Related topisc
• 3.1.
- AIR DIVE.
• 3.2.
- NITROX MIXTURES DIVE.
• 3.5.
- Decompression dive.
• 3.3.4. - CNS toxicity display.
• 3.3.5. - PO2 alarms.
• 4.1.2. - Logbook.
3.6. – program (depthometer/timer).
Archimedes
II
computer is equipped with a third dive com-
puting program ( program). This function is especially
useful for apnea (free diving) divers as well as for technical
dives with helium-based binary and ternary mixtures. Please
be advised that Archimedes
II
in program mode does
compute any saturation and de-saturation computations. It
functions only as a basic instrument offering depth and time
functions. During a dive conducted using the Gage mode,
proper decompression software must be utilized according
to proper dive tables.
Cressi-sub reminds you that sport dives must be carried out
within the no decompression guidelines, and at the maximum
depth of 132 ft., which is the limit of
sport diving: to exceed
such limits dramatically increases the risk of decompression
sickness!
WARNING:
Archimedes
II
computer has been developed
for sport diving only. It is not intended for commercial or pro-
fessional use requiring longer dive times, and greater diving
depths. Diving beyond the parameters of sport diving dra-
matically increases the risk of decompression sickness.
m
DANGER:
Cressi-sub discourages diving with gaseous
mixtures other than air without proper training. The use of
“technical” multi-gas mixtures may expose the diver to dif-
ferent risks than those of sport diving, including serious
physical damages and, in extreme cases, death.
Archimedes
II
computer’s diving program starts the
depth meter/timer functions automatically at depths deeper
than 5.0 ft., showing the following information on its display
(picture 22):
1
current depth value, in meters (m) or feet (ft.). The depth
meter’s operative range reaches a depth of m 199.9 (ft.
656).
ENGLISH
Archimede II 2006 3-11-2006 10:17 Pagina 181
Summary of Contents for Archimede II
Page 1: ...Manuale d istruzione Manuale d istruzione ITALIANO Archimede II 2006 3 11 2006 10 15 Pagina 1...
Page 2: ...Archimede II 2006 3 11 2006 10 15 Pagina 2...
Page 38: ...Archimede II 2006 3 11 2006 10 15 Pagina 38...
Page 79: ...Gebrauchsanweisung Gebrauchsanweisung DEUTSCH Archimede II 2006 3 11 2006 10 16 Pagina 79...
Page 94: ...3 W hrend des Tauchgangs 3 W hrend des Tauchgangs Archimede II 2006 3 11 2006 10 16 Pagina 94...
Page 118: ...118 BIANCA Archimede II 2006 3 11 2006 10 16 Pagina 118...
Page 134: ...3 En inmersi n 3 En inmersi n Archimede II 2006 3 11 2006 10 16 Pagina 134...
Page 159: ...User s Manual User s Manual ENGLISH Archimede II 2006 3 11 2006 10 17 Pagina 159...
Page 172: ...3 While diving 3 While diving Foto Ghisotti Archimede II 2006 3 11 2006 10 17 Pagina 172...
Page 194: ...194 Archimede II 2006 3 11 2006 10 17 Pagina 194...
Page 195: ...195 Archimede II 2006 3 11 2006 10 17 Pagina 195...
Page 196: ...196 Archimede II 2006 3 11 2006 10 17 Pagina 196...
Page 197: ...197 Archimede II 2006 3 11 2006 10 17 Pagina 197...
Page 198: ...Archimede II 2006 3 11 2006 10 17 Pagina 198...
Page 199: ...Archimede II 2006 3 11 2006 10 17 Pagina 199...