2.3

 

Inventory 

The complete product package should contain the following items. 

Quantity 

Item 

CTI-PS6 or CTI-PS6-M IP Power Strip 

1.5m crossover Ethernet patch cord for initial configuration 

2.4

 

Unpacking 

Confirm  that  the  package  includes  all  necessary  parts.  If  the  product  is  damaged  or  incomplete, 

contact your dealer for assistance. 

After unpacking, save the packaging materials so that they can be reused for further transport of the 

product or dispose of them appropriately (please recycle). 

   

 

2.5

 

Preparatory work before installation 

Before installation make sure to acquire knowledge about the Ethernet infrastructure the power strip 
will be operating in. In particular: 

-

 

Applicable IP subnet mask 

-

 

Default gateway 

-

 

Check for available IP addresses or check if the network allows DHCP service 

 
Also make sure that you have a proper web browser installed if you intend to use the IP power strip 
website. Supported browsers: 

-

 

Internet Explorer 9 

-

 

Mozilla Firefox 16 or higher 

-

 

Google Chrome 24 or higher 

-

 

Apple Safari 5.1 or higher 

 

 

Summary of Contents for CTI-PS6

Page 1: ...Creotech Instruments S A tel 48 22 233 10 27 ul Gen L Okulickiego 7 9 e mail support creotech pl 05 500 Piaseczno Polska www creotech pl IP POWER STRIP CTI PS6 CTI PS6 M v 3 5 10 2015 User s manual...

Page 2: ...9 2 6 Installing and assembling 10 2 6 1 First start up and configuration 10 2 6 1 1 Changing the network configuration of the PC for the first start up procedure 11 2 6 1 2 Logging in through the web...

Page 3: ...ection rating IP 2x Power supply 230 V AC 50 Hz Number of power outlets 6 Total output current 10 A Total output power 2300 W Power consumption 3 2 W 0 3 W per relay control unit only Operating ambien...

Page 4: ...its varistors Automatic hard reset of the connected devices by setting Maximum power consumption CTI PS6 M only The lack of response to the ping Scheduling switching sockets based on the calendar Remo...

Page 5: ...LEDs LINK ACT indicate the state of the Ethernet connection LINK LED ON The Ethernet link is up LINK LED OFF The Ethernet link is down ACT LED ON active data transfer ACT LED OFF no data transfer act...

Page 6: ...6 Creotech Instruments S A tel 48 22 233 10 27 ul Gen L Okulickiego 7 9 e mail support creotech pl 05 500 Piaseczno Polska www creotech pl 1 5 Technical drawing...

Page 7: ...ce or misapplication or has been altered or modified in any way Repair or replacement of a defective product does not extend the original warranty period Exclusions The Creotech Instruments S A shall...

Page 8: ...s product by yourself improper repair work can be dangerous Never disassemble or modify this product it may result in injury fire or electric shock Be sure to use the specified power source connection...

Page 9: ...r unpacking save the packaging materials so that they can be reused for further transport of the product or dispose of them appropriately please recycle 2 5 Preparatory work before installation Before...

Page 10: ...P Power Strip and switch the main switch on The power status LED should turn ON 2 Restore the factory settings refer to 4 2 3 Connect the IP Power Strip and a PC computer directly using crossover Ethe...

Page 11: ...bled Default outlet state all OFF To communicate with IP Power Strip for the first time it is required to change the network protocol settings of the computer used for the first configuration of the I...

Page 12: ...sly configured IP address The welcome page of IP Power Strip will be displayed IP Power Strip lets you create six user accounts and one administrator account The administrator has access to all settin...

Page 13: ...nded to be used in Static IP configuration can be used preferable or a DHCP IP Address static Subnet mask Default Gateway Enable Configure using DHCP option for DHCP configuration Double check the new...

Page 14: ...as it helps prevent large inrush current However it carries certain consequences which users need to be aware of when using specialized equipment or watchdog IP function If in managed network it is im...

Page 15: ...number name configurable in Configuration tab and state indicator WD Reset button is used to reset the watchdog of the socket if it has been turned off by it Details can be found in Section 3 3 It is...

Page 16: ...cheduler can be found in Scheduler tab To set the action for the socket you must first check the Active checkbox in outlet tab that you want to set up You can set two action for each socket per day Po...

Page 17: ...ending ping to the device again When three attempts to reset fail the output will be turned off permanently After a watchdog alarm to restore the normal functioning of the socket go to Outputs and pre...

Page 18: ...Above the time axis are shown device s response to the ping 1 means that the device answered 0 that it did not Under the time axis are shown the actions performed by IP power strip In the first case...

Page 19: ...in CTI PS6 M only From the menu on the left select a Watchdog Current group Activate the current watchdog function for the output by checking the Active checkbox Set the maximum current consumption a...

Page 20: ...can see whether the outlet is turned on or off and what actions are planned for him With writing permission you can change the state of the socket giving them names set the watchdog and action in sch...

Page 21: ...in the future This operation is safe because if a failure occurs you can return to the factory version of the firmware see section 4 3 To update the firmware download the latest update from the websit...

Page 22: ...power strip allows you to measure the electricity consumed by each output socket Go to Measurement tab Summary tab shows the current power consumption on the all outlets The tabs for each of the sock...

Page 23: ...hen select a Outputs group To specify individual name e g Computer 1 for each outlet modify Friendly name property To modify the outlet state after the power up change Power up state property Box chec...

Page 24: ...ction parameters are IP Address previously set IP address of the IP power strip Port number 23 Below is a table with a list of commands Description Command Status output show output on output number d...

Page 25: ...SNMP you can change and check the status of the outputs Commands for Firmware 1 34 and higher OID Type Description Device Reset 1 3 6 1 4 1 39525 1 INTEGER Set to positive value to reset Device info...

Page 26: ...14 3 1 1 1 1 6 ENUM IP watchdog active true 1 false 2 1 3 6 1 4 1 39525 5 14 3 1 1 2 1 6 OCTET STRING IP watchdog address 1 3 6 1 4 1 39525 5 14 3 1 1 2 1 6 INTEGER IP watchdog boottime 1 3 6 1 4 1 39...

Page 27: ...1 2 4 i 0 Check the state of the first socket snmpget c public v2c host 1 3 6 1 4 1 39525 11 1 2 0 Check the state of all sockets snmptable c public v2c host 1 3 6 1 4 1 39525 11 Check various values...

Page 28: ...cord from the IP Power Strip 2 Use a dry sponge to clean the product 3 Do not use aerosol cleaners alcohol thinner benzene etc to clean the product 4 Re plug the power cord Restoring the default sett...

Page 29: ...older 3 Remove and replace the blown fuse with the new fuse Make sure that the fuse is of the same type and current rating 5 mm x 20 mm 16 A 250 VAC slow blow fuse 4 Install the fuse holder door 5 Re...

Page 30: ...h switch router use regular CAT5 cable The configuration settings are not saved After the changes in configuration settings are made it is necessary to reboot the power strip in status tab Forgotten p...

Page 31: ...t creotech pl 05 500 Piaseczno Polska www creotech pl CTI PS6 MAN v3 5 10 2015 Entire contents copyright Creotech Instruments S A Reproduction in whole or in part without permission is prohibited Creo...

Reviews: