CI380X05R4_B

ANGLE ADJUSTMENT 

NOTE:

 Angle adjustment can be made before luminaire 

installation.

STEP 1:

After the luminaire is installed, the angle of the luminaire can 
be adjusted approximately 90° up or down in 5° increments. 

STEP 2: 

To adjust the angle, loosen the (2) 3/8" – 16 X 1.5" hex bolts 
located in the top section of the Mounting Clamp. See 

Figure 8.

 

NOTE:

 Do NOT remove hex bolts.

STEP 3: 

Using the Angle Bracket, shown in 

Figure 8, 

as a guide rotate 

the luminaire to the desired position and retighten the bolts 
loosened in Step 2 to 150 in.-lbs. 

LATERAL ADJUSTMENT

STEP 1:

The position of the luminaire can also be adjusted laterally. To 
adjust the Lateral position, loosen (2) 3/8" – 16 X 1.5" hex bolts 
located in the top section of the Mounting Clamp. See 

Figure 8. 

NOTE: 

Do NOT remove hex bolts.

STEP 2: 

Remove the Angle Bracket and (2) screws and set aside. See 

Figure 8

 

STEP 3: 

The Angle Bracket can be secured using the existing holes on 
the luminaire bar. Set the Mounting Clamp to desired lateral 
adjustment using the following positions on the bar  
(See 

Figure 9)

•  Position 1  - Left justification.
•  Position 3  - Center position (when angle bracket is on 

the left side of the mounting clamp).

•  Position 6  -  Center position (when angle bracket is 

on the right side of the mounting clamp).

•  Position 8  - Right justification.

NOTE:

 Positions 2, 4, 5 and 7 will not be able to be used.

NOTE:

 Mounting two luminaires to a 24" Bullhorn Tenon will 

require one luminaire mounted in position 1 and one luminaire 
mounted in position 8.

STEP 4:

Once desired position is achieved reinstall the Angle Bracket 
using (2) screws that were removed in Step 2. 

STEP 5:

Retighten hex bolts that were loosened in Step 1 to 
150 in-lbs.

NEMA

®

 RECEPTACLE (OPTIONAL) 

NOTE:

 Nema receptacle should only be used when mounting 

clamp is in horizontal position.

STEP 1: 

DO NOT loosen/tighten pan head screws for the NEMA 
receptacle.

STEP 2: 

Rotational adjustment of the photo control is tool-less.

STEP 3: 

Engage/install photo control into NEMA receptacle on top of the 
fixture.

STEP 4: 

Firmly rotate photo-control with its photo-eye 

approximately in the ‘N’ north direction. Some photo-

controls operate best somewhere between NW and NE.

Mounting 

Clamp

Angle 

Bracket

Angle Markings

Hex Bolts

Numbers on angle bracket are shown for illustration purpose 

only. Actual bracket doesn’t show numbers.

Washers

Square Mounting 

Plate

(4) 5/16”-18 

Supplied Fasteners

7

8

9

4

3

2

1

8

7

6

5

Angle Bracket is Shown in Position 3 in This Illustration

Mounting Clamp

Fitter

Nuts

Supply Cord

Summary of Contents for Edge XAKE Series

Page 1: ...ect power before installation DANGER Risque de choc Couper l alimentation avant l installation 2 This luminaire must be installed in accordance with the NEC or your local electrical code If you are not familiar with these codes and requirements consult a qualified electrician Ce produit doit être installé conformément à NEC ou votre code électrique local Si vous n êtes pas familier avec ces codes ...

Page 2: ...d fasteners secure the fitter to square mounting plate STEP 4 Route the supply cord coming from the luminaire through the Fitter and then through the pole See Figure 7 STEP 5 Complete Steps 4 and 5 of the Surface Mount Instructions UPLIGHT MOUNTING STEP 1 Remove 2 3 8 16 X 1 5 hex bolts located in the top section of the Mounting Clamp See Figure 5 STEP 2 Remove Mounting Clamp and flip the luminair...

Page 3: ...eft side of the mounting clamp Position 6 Center position when angle bracket is on the right side of the mounting clamp Position 8 Right justification NOTE Positions 2 4 5 and 7 will not be able to be used NOTE Mounting two luminaires to a 24 Bullhorn Tenon will require one luminaire mounted in position 1 and one luminaire mounted in position 8 STEP 4 Once desired position is achieved reinstall th...

Page 4: ...mming negative lead LINE OR HOT 1 GREEN LINE BLACK GROUND GREEN NEUTRAL WHITE DIM GREY DIM VIOLET NEUTRAL OR HOT 2 VIOLET GREY SUPPLY WIRING DIMMING OPTIONAL LUMINAIRE FIELD ADJUSTABLE DIMMING OPTIONAL STEP 1 This luminaire may be provided with field adjustable dimming Luminaires leave the factory adjusted to the maximum setting which is Position 9 as shown in Figure 10 STEP 2 Locate the luminaire...

Reviews: