3 of 4
CI380X05R4_B
ANGLE ADJUSTMENT
NOTE:
Angle adjustment can be made before luminaire
installation.
STEP 1:
After the luminaire is installed, the angle of the luminaire can
be adjusted approximately 90° up or down in 5° increments.
STEP 2:
To adjust the angle, loosen the (2) 3/8" – 16 X 1.5" hex bolts
located in the top section of the Mounting Clamp. See
Figure 8.
NOTE:
Do NOT remove hex bolts.
STEP 3:
Using the Angle Bracket, shown in
Figure 8,
as a guide rotate
the luminaire to the desired position and retighten the bolts
loosened in Step 2 to 150 in.-lbs.
LATERAL ADJUSTMENT
STEP 1:
The position of the luminaire can also be adjusted laterally. To
adjust the Lateral position, loosen (2) 3/8" – 16 X 1.5" hex bolts
located in the top section of the Mounting Clamp. See
Figure 8.
NOTE:
Do NOT remove hex bolts.
STEP 2:
Remove the Angle Bracket and (2) screws and set aside. See
Figure 8
STEP 3:
The Angle Bracket can be secured using the existing holes on
the luminaire bar. Set the Mounting Clamp to desired lateral
adjustment using the following positions on the bar
(See
Figure 9)
:
• Position 1 - Left justification.
• Position 3 - Center position (when angle bracket is on
the left side of the mounting clamp).
• Position 6 - Center position (when angle bracket is
on the right side of the mounting clamp).
• Position 8 - Right justification.
NOTE:
Positions 2, 4, 5 and 7 will not be able to be used.
NOTE:
Mounting two luminaires to a 24" Bullhorn Tenon will
require one luminaire mounted in position 1 and one luminaire
mounted in position 8.
STEP 4:
Once desired position is achieved reinstall the Angle Bracket
using (2) screws that were removed in Step 2.
STEP 5:
Retighten hex bolts that were loosened in Step 1 to
150 in-lbs.
NEMA
®
RECEPTACLE (OPTIONAL)
NOTE:
Nema receptacle should only be used when mounting
clamp is in horizontal position.
STEP 1:
DO NOT loosen/tighten pan head screws for the NEMA
receptacle.
STEP 2:
Rotational adjustment of the photo control is tool-less.
STEP 3:
Engage/install photo control into NEMA receptacle on top of the
fixture.
STEP 4:
Firmly rotate photo-control with its photo-eye
approximately in the ‘N’ north direction. Some photo-
controls operate best somewhere between NW and NE.
Mounting
Clamp
Angle
Bracket
Angle Markings
Hex Bolts
Numbers on angle bracket are shown for illustration purpose
only. Actual bracket doesn’t show numbers.
Washers
Square Mounting
Plate
(4) 5/16”-18
Supplied Fasteners
7
8
9
4
3
2
1
8
7
6
5
Angle Bracket is Shown in Position 3 in This Illustration
Mounting Clamp
Fitter
Nuts
Supply Cord