2 of 8
LPN00644X0007A0_A
SECTION 1:
ON GRID MOUNTING
INDIVIDUAL RECESSED MOUNTING
CAUTION:
Ceiling contractor must provide an uninterrupted,
continuous rough opening utilizing
tee grids
spaced at 4" center to
center. Length of opening should be determined from
Figure 3 on
next page.
Tee grids must be secured to structure above to support
weight of luminaire.
CAUTION:
Luminaires should be secured to structure above to
support weight of luminaire.
STEP 1:
Remove lens and upper LED/reflector tray and set aside in order of
run placement for reinstalling later. To remove lens, carefully slide
a plastic card or putty knife between the lens and extrusion towards
the end of the luminaire. Using the plastic card or putty knife, push
the lens inward until the lens comes free. See
Figure 1 and 2.
STEP 2:
After removing the lens, remove the Philips head reflector screws,
remove the LED Reflector Tray, and disconnect the LED harness.
Set lens and LED Reflector tray aside. See
Figure 1.
STEP 3:
Attach customer supplied support cables to luminaire and structure
above as shown in
Figure 1
:
STEP 4:
Using one of the 7/8” diameter holes on the end of the luminaire, install
customer supplied conduit and make electrical connections per
Section 5 “
Electrical Connections
”
STEP 5:
Reconnect LED harness. Replace LED trays and lens that was
removed in Step 1 & 2 above, ensure that no wires are pinched.
1
Support Cable
(Supplied By Others)
TO INSTALL:
Flexible Conduit
(Supplied By Others)
LED Tray
Lens
#10-18 X 1/4”
Phillips Head
Screws
2
Lens
Extrusion
Slide Plastic Card or
Putty Knife Here