background image

7 of 8

LPN00644X0007A0_A

SECTION 4:  

OFF GRID MOUNTING (HARD CEILING) - 
CONTINUOUS ROW RECESSED MOUNTING

CAUTION: 

Ceiling contractor must provide an uninterrupted, continuous 

rough opening. Dimensions of opening should be determined using 

Figure 7 on page 5 and Figure 9.
CAUTION:

 Luminaires should be secured to structure above to support 

weight of luminaire.

CAUTION:

 Do not attempt to assemble luminaire rows on the ground 

and then lift into position. This may create stress at the connection 
points and may result in damage and/or mechanical failure.

CAUTION: 

Do not connect power in a run  until all of run is installed, 

wire harnesses connected, and luminaire joints completed.

STEP 1: 

Remove lens and LED/reflector tray and  set aside in order of run 
placement for reinstalling later. To remove lens, carefully slide a plastic 
card or putty knife between the lens and extrusion towards the end 
of the luminaire. Using the plastic card or putty knife, push the lens 
inward until the lens come free. After removing the lens, remove the 
Philips head reflector screws, remove the LED Reflector Tray, and 
disconnect the LED harness. Set lens and LED Reflector tray aside. See 

Figure 2 and 6.

 

STEP 2:

Install the first luminaire (Right-Hand End of Run) from below into 
ceiling opening. Attach customer supplied threaded rods to luminaire 
through 5/8" mounting holes located on the top of the housing and to 
the structure above as shown in 

Figure 7 and 8

. Confirm that fixture

is pulled up firm to ceiling line.

STEP 3:

Position second luminaire in row such that it aligns with joint end (male 
end) of first luminaire. Attach customer supplied supports to fixture through 
mounting holes located on the top of the housing and to the structure above 
as shown in 

Figure 11

. Confirm that fixture is pulled up firm to ceiling line. 

Connect the second luminaire to the first luminaire as illustrated in 

Figure 

5

. Plug wire harness together and push excess wire into luminaire wiring 

chamber, ensure that no wires are pinched. See

 Figure 11.

STEP 4:

Push luminaires tightly together while making sure the alignment pins 

slide into the interior tracks of each luminaire and span the luminaire 

joint. Secure joint by tightening supplied keps locknuts on threaded 

studs of male joiner bracket. Confirm that luminaires are secured to the 
structure above. See 

Figure 11.

STEP 5:

Continue to install and assemble row following steps 1-4 above. Using 

one of the 7/8" dia. holes on the End unit (Left-Hand End of Run) 

luminaire, install conduit connector and make electrical connections 

per Section 5 “Electrical Connections”. 

STEP 6:

Reconnect LED harness. Replace LED trays and lens that was removed 

in Step 1 above, ensure that no wires are pinched..

STEP 7:

Hard Ceiling, Overlap Flange Only:
Fill in Sheet Rock mud over tapered extruded flange until smooth. See 

Figure 10.

11

Second Luminaire

First Luminaire

Male End

Female End

Wire Harness

Summary of Contents for Stylus Series

Page 1: ...icien qualifié 3 SUITABLE FOR CONTINUOUS ROW MOUNTING PEUT ÊTRE MONTÉ EN RANGÉE CONTINUE 4 Suitable for Damp Locations Convient aux emplacements humides 5 MIN 90C SUPPLY CONDUCTORS LES FILS D ALIMENTATION 90C MIN 6 INHERENTLY PROTECTED 7 TYPE IC VAPOR BARRIER MUST BE SUITABLE FOR 90C TYPE IC LE PARE VAPEUR DOIT CONVENIR POUR 90 C PROTECTION INHERENTE 8 Make sure the equipment is properly grounded ...

Page 2: ...ire Using the plastic card or putty knife push the lens inward until the lens comes free See Figure 1 and 2 STEP 2 After removing the lens remove the Philips head reflector screws remove the LED Reflector Tray and disconnect the LED harness Set lens and LED Reflector tray aside See Figure 1 STEP 3 Attach customer supplied support cables to luminaire and structure above as shown in Figure 1 STEP 4 ...

Page 3: ...alled with threaded rod to structure above by others and should be installed accordance with these instructions Plugged holes for threaded rod attachment are located 4in from both ends of each luminaire 23 25 0 19 Endcap Thickness 0 19 47 25 71 25 95 25 119 25 143 25 0 19 Endcap Thickness 0 19 Endcap Thickness 0 19 Endcap Thickness 0 19 Endcap Thickness 0 19 Endcap Thickness 0 19 Endcap Thickness ...

Page 4: ... 7 In order to install the end cap on the male end of the luminaire replace the male joiner bracket with the female joiner bracket and remove the alignment pins See Figure 4 and 6 STEP 3 Lay the first luminaire Right Hand End of the Row into the grid per Figure 7 grid requirements STEP 4 Position second luminaire in row such that it aligns with joint end male end of first luminaire Attach using cu...

Page 5: ...7 8 7 8 8 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 50 52 54 56 58 60 26 28 30 32 34 36 38 40 42 44 46 48 62 64 66 68 70 72 Trim Length for Endcaps in For On Grid Mounting ONLY Continous Row Length in End Cap to End Cap LUMINAIRE ROW LAYOUT EXAMPLE OF A THREE UNIT 20 24 CAN BE MOUNTED IN OTHER CONFIGURATIONS 7 86 7 8 86 7 8 38 7 8 237 1 16 End Cap to End Cap 236 1 16 Aperture 284...

Page 6: ...8 STEP 2 Using one of the 7 8 dia holes on the end of the fixture install conduit connector See Figure 8 STEP 3 Install fixture from below into ceiling opening Attach customer supplied threaded rods to luminaire through 5 8 mounting holes located on the top of the housing and to the structure above as shown in Figure 8 Confirm that fixture is pulled up firm to ceiling line STEP 4 Make electrical c...

Page 7: ...s located on the top of the housing and to the structure above as shown in Figure 7 and 8 Confirm that fixture is pulled up firm to ceiling line STEP 3 Position second luminaire in row such that it aligns with joint end male end of first luminaire Attach customer supplied supports to fixture through mounting holes located on the top of the housing and to the structure above as shown in Figure 11 C...

Page 8: ...supply dimming negative lead If dimming is not being used ensure to cap off the grey lead GREEN LINE BLACK GROUND GREEN NEUTRAL WHITE DIM GREY DIM VIOLET VIOLET GREY CORD SUPPLY WIRING LUMINAIRE NEUTRAL OR HOT 2 LINE OR HOT 1 FCC NOTICE CAUTION Changes or modifications not expressly approved could void your authority to use this equipment This device complies with part 15 of the FCC Rules Operatio...

Reviews: