9
IMPOR
TANT !
1.)
MOISTURE
AND
TEMPERA
TURE
SENSORS
MUST
BE CONNECTED
TO V
ALIDA
TE
THE CSA
LISTING.
2.)
A SPECIAL
MOISTURE SENSOR RELA
Y IS REQUIRED IN
THE CONTROL
P
ANEL
FOR PROPER OPERA
TION OF
THE MOISTURE SENSORS.CONT
ACT
CP&S FOR INFORMA
TION CONCERNING MOISTURE SENSING RELA
YS FOR
CUST
OMER SUPPLIED CONTROL
P
ANELS.
3.)
THESE PUMPS
ARE CSA
LISTED FOR PUMPING W
ATER
AND W
ASTEW
ATER.
DO NOT USE T
O PUMP
FLAMMABLE LIQUIDS
. NOT
SUIT
ABLE FOR ENVIRONMENTS CONT
AINING GASOLINE OR HEXANE.
4.)
INST
ALLA
TIONS SUCH
AS DECORA
TIVE FOUNT
AINS OR W
ATER FEA
TURES PROVIDED FOR VISUAL
ENJOYMENT
MUST
BE INST
ALLED IN
ACCORDANCE WITH
THE NA
TIONAL
ELECTRIC CODE
ANSI/NFP
A 70
AND/OR
THE
AUTHORITY
HA
VING JURISDICTION.
THIS PUMP
IS NOT
INTENDED FOR USE IN SWIMMING POOLS, RECREA
TIONAL
W
ATER P
ARKS, OR INST
ALLA
TIONS IN WHICH HUMAN CONT
ACT
WITH PUMPED MEDIA
IS
A COMMON OCCURRENCE.
5.)
A
NON-SP
ARKING
BREAKA
W
AY
FITTING MUST
BE USED
TO V
ALIDA
TE
THE EXPLOSION PROOF LISTING.
6.)
WINDING RESIST
ANCE
± 7.5%. WINDING RESIST
ANCE MEASURED IN OHMS @ 25°C (BETWEEN LINES)
AT
MOT
OR LEADS.
7.)
PUMP
RA
TED FOR OPERA
TION
AT
± 10% VOL
TAGE
AT
MOT
OR.
**
SELECT
IMPELLER DIAMETER WHEN ORDERING.
MODEL NO
.
SIZE
IMP
. DIA.
INCHES
(MM)
HP
V
O
LT
PH
HZ
RPM
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
TO
R
AMPS
DRIVER FRAME
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
7365N-X52-95-30N
10DL
14.76 (375)
50
460
3
60
1150
H
76.4
1.15
84.0
400.0
5
138318
6/4 - 18/4
6/4-18/4
.130
7365N-X52-1E-30N
10DL
14.76 (375)
50
575
3
60
1150
H
61.2
1.15
67.2
320.0
5
138318
6/4 - 18/4
6/4-18/4
.189
7365N-X52-96-30N
10DL
15.35 (390)
60
460
3
60
1150
F
86.7
1.15
96.8
400.0
5
138319
2/4 - 18/4
2/4-18/4
.130
7365N-X52-1F-30N
10DL
15.35 (390)
60
575
3
60
1150
F
69.4
1.15
77.4
320.0
5
138318
6/4 - 18/4
6/4-18/4
.189
7365N-X52-67-30N
10DL
16.14 (410)
75
460
3
60
1150
H
109.3
1.15
119.5
612.0
5
138319
2/4 - 18/4
2/4-18/4
.077
7365N-X52-82-30N
10DL
16.14 (410)
75
575
3
60
1150
H
87.4
1.15
95.6
489.6
5
138319
2/4 - 18/4
2/4-18/4
.1
13
7365N-X52-68-30N
10DL
17.32 (440)
100
460
3
60
1150
E
135.0
1.0
135.0
612.0
5
138319
2/4 - 18/4
2/4-18/4
.077
7365N-X52-83-30N
10DL
17.32 (440)
100
575
3
60
1150
E
108.0
1.0
108.0
489.6
5
138319
2/4 - 18/4
2/4-18/4
.1
13
7365N-X53-94-30N
10DL
17.32 (440)
40
460
3
60
870
F
62.2
1.15
69.4
275.0
5
138318
6/4 - 18/4
6/4-18/4
.166
7365N-X53-1D-30N
10DL
17.32 (440)
40
575
3
60
870
F
49.8
1.15
55.5
220.0
5
138317
8/4 - 18/4
8/4-18/4
.226
7365N-X53-95-30N
10DL
17.91 (455)
50
460
3
60
870
D
74.5
1.15
84.9
275.0
5
138318
6/4 - 18/4
6/4-18/4
.166
7365N-X53-1E-30N
10DL
17.91 (455)
50
575
3
60
870
D
59.0
1.15
67.4
220.0
5
138317
8/4 - 18/4
8/4-18/4
.226
7365N-X54-95-30N
10DH
13.98 (355)
50
460
3
60
1150
H
76.4
1.15
84.0
400.0
5
138318
6/4 - 18/4
6/4-18/4
.130
7365N-X54-1E-30N
10DH
13.98 (355)
50
575
3
60
1150
H
61.2
1.15
67.2
320.0
5
138318
6/4 - 18/4
6/4-18/4
.189
7365N-X54-96-30N
10DH
14.17 (360)
60
460
3
60
1150
F
86.7
1.15
96.8
400.0
5
138319
2/4 - 18/4
2/4-18/4
.130
7365N-X54-1F-30N
10DH
14.17 (360)
60
575
3
60
1150
F
69.4
1.15
77.4
320.0
5
138318
6/4 - 18/4
6/4-18/4
.189
▲
CORD SOLD SEP
ARA
TEL
Y. CORD SUFFIX: XF - 50 FEET
, XJ - 75 FEET
, OR XL
- 100 FEET
.
CHART ‘D’