6
IMPOR
TANT !
1.)
MOISTURE
AND
TEMPERA
TURE
SENSORS
MUST
BE CONNECTED
TO V
ALIDA
TE
THE CSA
LISTING.
2.)
A SPECIAL
MOISTURE SENSOR RELA
Y IS REQUIRED IN
THE CONTROL
P
ANEL
FOR PROPER OPERA
TION OF
THE MOISTURE SENSORS.CONT
ACT
CP&S FOR INFORMA
TION CONCERNING MOISTURE SENSING RELA
YS FOR
CUST
OMER SUPPLIED CONTROL
P
ANELS.
3.)
THESE PUMPS
ARE CSA
LISTED FOR PUMPING W
ATER
AND W
ASTEW
ATER.
DO NOT USE T
O PUMP
FLAMMABLE LIQUIDS
. NOT
SUIT
ABLE FOR ENVIRONMENTS CONT
AINING GASOLINE OR HEXANE.
4.)
INST
ALLA
TIONS SUCH
AS DECORA
TIVE FOUNT
AINS OR W
ATER FEA
TURES PROVIDED FOR VISUAL
ENJOYMENT
MUST
BE INST
ALLED IN
ACCORDANCE WITH
THE NA
TIONAL
ELECTRIC CODE
ANSI/NFP
A 70
AND/OR
THE
AUTHORITY
HA
VING JURISDICTION.
THIS PUMP
IS NOT
INTENDED FOR USE IN SWIMMING POOLS, RECREA
TIONAL
W
ATER P
ARKS, OR INST
ALLA
TIONS IN WHICH HUMAN CONT
ACT
WITH PUMPED MEDIA
IS
A COMMON OCCURRENCE.
5.)
A
NON-SP
ARKING
BREAKA
W
AY
FITTING MUST
BE USED
TO V
ALIDA
TE
THE EXPLOSION PROOF LISTING.
6.)
WINDING RESIST
ANCE
± 7.5%. WINDING RESIST
ANCE MEASURED IN OHMS @ 25°C (BETWEEN LINES)
AT
MOT
OR LEADS.
7.)
PUMP
RA
TED FOR OPERA
TION
AT
± 10% VOL
TAGE
AT
MOT
OR.
** SELECT
IMPELLER DIAMETER WHEN ORDERING.
MODEL NO
.
SIZE
IMP
. DIA.
INCHES
(MM)
HP
V
O
LT
PH
HZ
RPM
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
TO
R
AMPS
DRIVER FRAME
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
7365N-412-67-30N
4MH
14.57 (370)
75
460
3
60
1750
G
108.4
1.15
120.7
578.0
5
138319
2/4 - 18/4
2/4 - 18/4
.095
7365N-412-82-30N
4MH
14.57 (370)
75
575
3
60
1750
G
86.7
1.15
96.6
462.4
5
138319
2/4 - 18/4
2/4 - 18/4
.095
7365N-414-67-30N
4DH
13.00 (330)
75
460
3
60
1750
G
108.4
1.15
120.7
578.0
5
138319
2/4 - 18/4
2/4 - 18/4
.070
7365N-414-82-30N
4DH
13.00 (330)
75
575
3
60
1750
G
86.7
1.15
96.6
462.4
5
138319
2/4 - 18/4
2/4 - 18/4
.095
7365N-414-68-30N
4DH
14.57 (370)
100
460
3
60
1750
E
136.6
1.15
155.3
578.0
5
138319
2/4 - 18/4
2/4 - 18/4
.070
7365N-414-83-30N
4DH
14.57 (370)
100
575
3
60
1750
E
109.2
1.15
124.2
462.4
5
138319
2/4 - 18/4
2/4 - 18/4
.095
7365N-617-67-30N
6MH
13.78 (350)
75
460
3
60
1750
G
108.4
1.15
120.7
578.0
5
138319
2/4 - 18/4
2/4-18/4
.070
7365N-617-82-30N
6MH
13.78 (350)
75
575
3
60
1750
G
86.7
1.15
96.6
462.4
5
138319
2/4 - 18/4
2/4-18/4
.095
7365N-617-68-30N
6MH
14.37 (365)
100
460
3
60
1750
E
136.6
1.15
155.3
578.0
5
138319
2/4 - 18/4
2/4-18/4
.070
7365N-617-83-30N
6MH
14.37 (365)
100
575
3
60
1750
E
109.2
1.15
124.2
462.4
5
138319
2/4 - 18/4
2/4-18/4
.095
7365N-618-67-30N
6D
13.19 (335)
75
460
3
60
1750
G
108.4
1.15
120.7
578.0
5
138319
2/4 - 18/4
2/4-18/4
.070
7365N-618-82-30N
6D
13.19 (335)
75
575
3
60
1750
G
86.7
1.15
96.6
462.4
5
138319
2/4 - 18/4
2/4-18/4
.095
7365N-618-68-30N
6D
13.98 (355)
100
460
3
60
1750
E
136.6
1.15
155.3
578.0
5
138319
2/4 - 18/4
2/4-18/4
.070
7365N-618-83-30N
6D
13.98 (355)
100
575
3
60
1750
E
109.2
1.15
124.2
462.4
5
138319
2/4 - 18/4
2/4-18/4
.095
7365N-618-69-30N
6D
14.57 (370)
125
460
3
60
1750
F
169.4
1.15
191.5
800.0
5
138320
1/0/4
- 18/4
1/0/4-18/4
.049
7365N-618-84-30N
6D
14.57 (370)
125
575
3
60
1750
F
135.6
1.15
153.2
640.0
5
138319
2/4 - 18/4
2/4-18/4
.065
7365N-633-67-30N
6V
11.61 (295)
75
460
3
60
1750
G
108.4
1.15
120.7
578.0
5
138319
2/4 - 18/4
2/4 - 18/4
.070
7365N-633-82-30N
6V
11.61 (295)
75
575
3
60
1750
G
86.7
1.15
96.6
462.4
5
138319
2/4 - 18/4
2/4 - 18/4
.095
7365N-633-68-30N
6V
13.00 (330)
100
460
3
60
1750
E
136.6
1.15
155.3
578.0
5
138319
2/4 - 18/4
2/4-18/4
.070
7365N-633-83-30N
6V
13.00 (330)
100
575
3
60
1750
E
109.2
1.15
124.2
462.4
5
138319
2/4 - 18/4
2/4-18/4
.095
▲
CORD SOLD SEP
ARA
TEL
Y. CORD SUFFIX: XF - 50 FEET
, XJ - 75 FEET
, OR XL
- 100 FEET
.
CHART ‘A
’
Summary of Contents for DEMING 7365N-X54-95-30N
Page 18: ...18 FIGURE 9 Vortex Enclosed CROSS SECTIONS FIGURE 10 ...
Page 19: ...19 EXPLODED VIEWS FIGURE 11 ...
Page 22: ...22 Notes ...