Place spring retainer and spring onto motor shaft. Lightly 
oil shaft 

(DO NOT use grease)

 and inner surface of 

bellows of rotating member. With fi nished end away from 
motor, slide rotating member over bullet and onto shaft 
until it engages spring (see Fig. 9). Carefully assemble 
shaft to seal plate as per section F-3.3. It is extremely 
important to keep seal faces clean during assembly. Dirt 
particles lodged between these faces will cause the seal 
to leak. When seal plate is assembled to motor, it will 
properly align and seat the seal (3) and bearing (4). Follow 
complete reassembly instructions as per section F-3.3.

F-4.3)  Replacing Exclusion Seal:

The exclusion seal (14), helps to keep debris away from the 
shaft seal where it could cause damage. The exclusion seal 
should be replaced whenever the shaft seal is replaced. To 
replace the exclusion seal, pull the old seal off the shaft, and 
slide the new seal on with the thin lip toward the motor. Be 
sure not to damage the lip of the seal. Finger pressure is all 
that is needed to install the exclusion seal.

SECTION: G REPLACEMENT PARTS

G-1 ORDERING REPLACEMENT PARTS:

When ordering replacement parts, ALWAYS furnish the 
following information:

1. Pump serial number and date code. (Paragraph G-4)
2. Pump model number. (Paragraph G-3)
3. Pump part number. (Paragraph G-2)
4. Part description.
5. Item part number.
6. Quantity required.
7. Shipping instructions.
8. Billing Instructions.

G-2 PART NUMBER:

The part number consists of a six (6) digit number, which 
appears in the catalog. A one or two letter suffi x may follow 
this number to designate the design confi guration. This 
number is used for ordering and obtaining information.

G-3 MODEL NUMBER:

This designation consists of numbers and letters which 
represent the discharge size, series, horsepower, motor 
phase and voltage, speed and pump design. This number is 
used for ordering and obtaining information.

G-4 SERIAL NUMBER:

The serial number block will consist of a six digit number, 
which is specifi c to each pump and may be preceded by 
an alpha character, which indicates the plant location. 
This number will also be suffi xed with a four digit number, 
which indicates the date the unit was built (Date Code). 

EXAMPLE: A012345 0490

.

Reference the six digit portion (Serial Number) of this 
number when referring to the product.

Rotating Member (3c)

Motor, Sleeve & 
Bearing

Bullet

Seal Pusher

FIGURE 9

Spring

Retaining Ring (3a)

Exclusion Seal

Bearing (4)

Seal Plate

Spring (3b)

Retaining Ring (5)

Stationary (3d)
Polished Mating Surface

Rotating Member (3c)

Sleeve

MOTOR END

(Inboard End)

PUMP END

(Outboard End)

FIGURE 8

Retaining Ring (3a)

Summary of Contents for Barnes SE411HT

Page 1: ...stant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 107027A Rev D Series SE411HT 4Hp 1750 RPM 60 Hz Manual Index ...

Page 2: ...NS 3 A PUMP SPECIFICATIONS 4 B GENERAL INFORMATION 5 C INSTALLATION INSTRUCTIONS 5 6 D START UP OPERATION 7 E PREVENTATIVE MAINTENANCE 7 F SERVICE AND REPAIR 7 10 G REPLACEMENT PARTS 10 TROUBLE SHOOTING 11 CROSS SECTION Fig 10 12 PARTS LIST 13 RETURN GOODS POLICY 15 WARRANTY START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS and EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL TOOL KIT s...

Page 3: ...ings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed...

Page 4: ...nless Steel PAINT Air Dry Enamel SEAL Design Single Mechanical Reservoir Secondary Exclusion Seal Material Carbon Ceramic Buna N Hardware 300 Series Stainless CORD ENTRY 15 ft 5m Cord with plug On 115 volt and Stainless Wire Mesh Strain Relief Pressure Gromment for sealing and strain relief SPEED 1750 RPM nominal UPPER BEARING Single Row Ball Oil Lubricated LOWER BEARING Single Row Ball Oil Lubric...

Page 5: ...nes representative or Crane Pumps Systems Inc Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Bramton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location These pumping units are self contained and are recommended for use in a sump or basin The sump or basin shall be vented in accordance with local plumbing codes This pump is designed to pump effluent ...

Page 6: ...t be modified in any way except for shortening to a specific application Any splice between the pump and the control panel must be made in accordance with the electric codes It is recommended that a junction box if used be mounted outside the sump or be of at least NEMA 4 EEMAC 4 construction if located within the wet well Do not use the power cable to lift pump NOTE THE WHITE WIRE IS NOT A NEUTRA...

Page 7: ...nd allowing the pump to operate through it s pumping cycle The time needed to empty the system or pump down time should be recorded on the start up sheet SECTION E PREVENTATIVE MAINTENANCE As the motor is oil filled no lubrication or other maintenance is required and generally Barnes pumps will give very reliable service and can be expected to operate for years on normal sewage pumping without fai...

Page 8: ...on around the sealed areas and inspect joints for air bubbles If after five minutes the pressure is still holding constant and no bubbles are observed slowly bleed the pressure and remove the gauge assembly Replace the pipe plug using a sealant If the pressure does not hold then the leak must be located CAUTION Pressure builds up extremely fast increase pressure by TAPPING air nozzle Too much pres...

Page 9: ...ate 2 and tighten motor screws Install o ring 11 onto seal plate 2 Slide the gland nut friction rings and grommet onto cord set see Figure 5 and slip cord through motor housing 12 Connect motor wires per Figure 6 Place motor housing 12 squarely onto seal plate while pulling excess cord through hole Tighten socket head screws 13 into motor housing Slide the friction rings 8b grommet 8c and gland nu...

Page 10: ... serial number and date code Paragraph G 4 2 Pump model number Paragraph G 3 3 Pump part number Paragraph G 2 4 Part description 5 Item part number 6 Quantity required 7 Shipping instructions 8 Billing Instructions G 2 PART NUMBER The part number consists of a six 6 digit number which appears in the catalog A one or two letter suffix may follow this number to designate the design configuration Thi...

Page 11: ...eller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as...

Page 12: ...12 FIGURE 10 ...

Page 13: ... 2 051449 Friction Ring 8c 1 051451 Grommet 8d 1 108335A Wire Mesh Cord Grip 304 Stainless 8e 1 108336 Hex Nut 1 2 Stainless 10 1 016660 Self Tapping Screw 8 32 x 3 8 lg Stainless 11 1 019289 O Ring 12 1 093065A Motor Housing 13 2 084948 Socket Hd Cap Screw 1 4 20 x 1 25 Stainless 14 1 068053 Exclusion Seal 15 1 112561TE Impeller Cast Iron 16 1 099295 Ground Wire 17 1 068984 Gasket 18 1 089120A Vo...

Page 14: ...formance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATI...

Page 15: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...