Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY

 and to 

PREVENT 

EQUIPMENT PROBLEMS.

 To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury orIndicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION!

 Warns about hazards that 

can or will cause minor

 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING!

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only qualifi 

ed personnel should install, operate and repair 

pump. Any wiring of pumps should be performed by a qualifi ed 
electrician.

WARNING !

 To reduce risk of electrical shock, pumps and 

control panels must be properly grounded in accordance 
with the National Electric Code (NEC) or the Canadian 
Electrical Code (CEC) and all applicable state, province, 
local codes and ordinances. Improper grounding voids 
warranty.

WARNING!

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag. 

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

CAUTION !

 Never operate a pump with a plug-in  type 

power cord without a ground fault  circuit interrupter.

 

CAUTION !

 Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing.

 

WARNING !

 Do not pump hazardous materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

 

CAUTION !

 

Do not

 block or restrict discharge hose, as 

discharge hose may whip under pressure.

 

WARNING !

 Do not wear loose clothing that may  

become entangled in moving parts.

  

WARNING !

 Keep clear of suction and discharge 

openings. 

DO NOT 

insert fi ngers in pump with power 

connected.  

Always wear eye protection when working on pumps. 

Make sure lifting handles are securely fastened each 

 

time before lifting. 

DO NOT

 operate pump without safety 

devices in place. Always replace safety devices that 

 

have been removed during service or repair. Secure the 
pump in its operating position so it can not tip over, fall  
or slide.

 

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor  
to overheat.

 

DO NOT

 remove cord and strain relief. 

DO NOT

 connect 

conduit to pump.

 

WARNING !

 Cable should be protected at all times to  

avoid punctures, cut, bruises and abrasions. Inspect 
frequently. Never handle connected power cords with 

 

wet hands.

 

WARNING !

 To reduce risk of electrical shock, all  wiring 

and junction connections should be made per  the NEC 
or CEC and applicable state or province and  local 
codes. Requirements may vary depending on  usage 
and location.

 

WARNING!

 Submersible Pumps are not approved for 

 

use in swimming pools, recreational water installations 
decorative fountains or any installation where human 
contact with the pumped fl uid is common.

  

WARNING!

 Products returned must be cleaned, 

sanitized, or decontaminated as necessary prior to 
shipment, to insure that employees will not be exposed 
to health hazards in handling said material. All Applicable 
Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fi tted pumps may 
contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in  potable water 
applications. For non-leaded copper  alloy materials of 
construction, please contact factory.

 

Crane Pumps & Systems, Inc. is not responsible for 
losses, injury, or death resulting from a failure to observe 
these safety precautions, misuse or abuse of pumps or 
equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Summary of Contents for Barnes SE411HT

Page 1: ...stant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 107027A Rev D Series SE411HT 4Hp 1750 RPM 60 Hz Manual Index ...

Page 2: ...NS 3 A PUMP SPECIFICATIONS 4 B GENERAL INFORMATION 5 C INSTALLATION INSTRUCTIONS 5 6 D START UP OPERATION 7 E PREVENTATIVE MAINTENANCE 7 F SERVICE AND REPAIR 7 10 G REPLACEMENT PARTS 10 TROUBLE SHOOTING 11 CROSS SECTION Fig 10 12 PARTS LIST 13 RETURN GOODS POLICY 15 WARRANTY START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS and EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL TOOL KIT s...

Page 3: ...ings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed...

Page 4: ...nless Steel PAINT Air Dry Enamel SEAL Design Single Mechanical Reservoir Secondary Exclusion Seal Material Carbon Ceramic Buna N Hardware 300 Series Stainless CORD ENTRY 15 ft 5m Cord with plug On 115 volt and Stainless Wire Mesh Strain Relief Pressure Gromment for sealing and strain relief SPEED 1750 RPM nominal UPPER BEARING Single Row Ball Oil Lubricated LOWER BEARING Single Row Ball Oil Lubric...

Page 5: ...nes representative or Crane Pumps Systems Inc Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Bramton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location These pumping units are self contained and are recommended for use in a sump or basin The sump or basin shall be vented in accordance with local plumbing codes This pump is designed to pump effluent ...

Page 6: ...t be modified in any way except for shortening to a specific application Any splice between the pump and the control panel must be made in accordance with the electric codes It is recommended that a junction box if used be mounted outside the sump or be of at least NEMA 4 EEMAC 4 construction if located within the wet well Do not use the power cable to lift pump NOTE THE WHITE WIRE IS NOT A NEUTRA...

Page 7: ...nd allowing the pump to operate through it s pumping cycle The time needed to empty the system or pump down time should be recorded on the start up sheet SECTION E PREVENTATIVE MAINTENANCE As the motor is oil filled no lubrication or other maintenance is required and generally Barnes pumps will give very reliable service and can be expected to operate for years on normal sewage pumping without fai...

Page 8: ...on around the sealed areas and inspect joints for air bubbles If after five minutes the pressure is still holding constant and no bubbles are observed slowly bleed the pressure and remove the gauge assembly Replace the pipe plug using a sealant If the pressure does not hold then the leak must be located CAUTION Pressure builds up extremely fast increase pressure by TAPPING air nozzle Too much pres...

Page 9: ...ate 2 and tighten motor screws Install o ring 11 onto seal plate 2 Slide the gland nut friction rings and grommet onto cord set see Figure 5 and slip cord through motor housing 12 Connect motor wires per Figure 6 Place motor housing 12 squarely onto seal plate while pulling excess cord through hole Tighten socket head screws 13 into motor housing Slide the friction rings 8b grommet 8c and gland nu...

Page 10: ... serial number and date code Paragraph G 4 2 Pump model number Paragraph G 3 3 Pump part number Paragraph G 2 4 Part description 5 Item part number 6 Quantity required 7 Shipping instructions 8 Billing Instructions G 2 PART NUMBER The part number consists of a six 6 digit number which appears in the catalog A one or two letter suffix may follow this number to designate the design configuration Thi...

Page 11: ...eller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as...

Page 12: ...12 FIGURE 10 ...

Page 13: ... 2 051449 Friction Ring 8c 1 051451 Grommet 8d 1 108335A Wire Mesh Cord Grip 304 Stainless 8e 1 108336 Hex Nut 1 2 Stainless 10 1 016660 Self Tapping Screw 8 32 x 3 8 lg Stainless 11 1 019289 O Ring 12 1 093065A Motor Housing 13 2 084948 Socket Hd Cap Screw 1 4 20 x 1 25 Stainless 14 1 068053 Exclusion Seal 15 1 112561TE Impeller Cast Iron 16 1 099295 Ground Wire 17 1 068984 Gasket 18 1 089120A Vo...

Page 14: ...formance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATI...

Page 15: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Page 16: ...Notes ...