11.
MACHINE CONFIGURATION
....Press the icon to bring up the first screen.
Pressing the Machine Configuration icon brings up a screen listing the Machine Configuration menu
items. Note: Of the items listed below, Firmware Information on this initial screen is view only and
cannot be changed at this point in the programming. They are for information purposes only. They may
be changed at other menu locations in the programming.
Refrigeration Settings – Press the Refrigeration Settings icon.
Pressing the icon will bring up options for controlling the temperature and health control settings. When
the health control features are not in use the control options will not appear.
Press an icon to choose the desired option. Choosing the
desired option will either bring up a screen or open a
window to proceed.
Press the Refrigeration Set Point
icon will open up a
window allowing you to set a new temperature (set point)
for initial pull down and reload recovery using numeric
icons. The vender leaves the factory set at 37°F
(temperature set must be between 32º and 75º F or 0º and
23.8º C). Use the Done icon to lock in the new setting.
Press the Storage Set Point
icon will open up a window allowing you to set a new temperature (set
point) for storage temperature using the numeric icons. The vender leaves the factory set at 45°F
(temperature set must be between 32º and 75º F or 0º and 23.8º C). Use the Done icon to lock in the
new setting. Storage time must be set and Storage Temp Enabled for this Temperature setting to work.
Press the Recheck Allowed
icon will toggle Recheck Allowed from Yes to No. When set to Yes after a
“HEALTH TIME” error has occurred, the vender will recheck the cooler compartment temperature 3
times in 15-minute intervals. If the temperature drops below 41°F, the “HEALTH TIME” error is
cleared and selections are re-enabled. If any recheck reads above a previous reading, or if the
temperature is not below 41°F by the third recheck, the “HEALTH TIME” error will remain and
selections will continue to be blocked.
Machine Configuration
Refrigeration Settings >
Space To Sales
On Off
Picker Cup Sensor
On
Off
Port Sensor
On
Off
Manual Key Switch Override >
Firmware Information >
Cabinet Offsets >
EVS Compliance
No
Shelf Location
D2
Model Number
3800 5800
Encoder Resolution
3310 counts/inch
Refrigeration Settings
Refrigeration Set Point 50°F
Storage Set Point 45°F
Recheck Allowed
No Yes
Temperature Units Fahrenheit (°F)
Health Control >