Press the Done icon to save selection and return to the Factory Setup menu. Press the
X
icon to move
backward 1 step in the menu.
Press the Model Number icon to toggle the model number from 3800 to 5800.
Press the Shelf Offset icon to enter the Shelf Offset option and
open a window that will allow you to change the setting. The
factory default setting is 700.
Adjust Shelf (Y) Offset (up and down). To change the offset
enter a new number (3310 counts = 1 inch) and press the Done
icon to save and display will show Shelf Offset ###. Press the
X
icon to move backward 1 step in the
menu.
Press the Next Step icon will scroll to the next item available
and bring up a screen with the option. Press the Diagnostics
icon will list any errors registered.
Press the Set Initial Defaults will make the changes listed on
display and the display will move to the Next step.
Press the Move to 502 icon and the platform moves to the
502 position. The icon text changes to Cycle Cup Plunger,
which causes the plunger to cycle when pressed. The icon
text then changes to Move to 508 and repeats process for 108
and 102. Then the test is complete with an icon message
stating the platform will be homed when the Next icon is
pressed. Note: Make sure the left door switch is activated
(pulled to the out position) so that the motors are powered. If
this switch is not pulled out, then the motors won’t move and nothing will happen.
Press the Next Step icon will scroll forward through the
available options of settings to adjust. Press the Diagnostics
icon will list any errors registered. Press the Move to Swipe
Position icon will move the Delivery (Picker) Cup to the
delivery position at the Port opening. Make sure the door
switch is activated so that the motors are powered. If this
switch is not pulled out, then the motors won’t move and
nothing will happen.
Machine Configuration
Model Number
3800 5800
Factory Setup
Shelf Offset
700
Factory Setup
Next Step >
Diagnostics >
Set Test Defaults
Press the button to set the price for all
selections to 0.00, the temperature
setpoint to 50 degrees F and Rapid
Set Initial Defaults >
Factory Setup
Next Step >
Diagnostics >
Platform Movement Test
Move to 502 >
Factory Setup
Next Step >
Diagnostics >
Hook Swipe Position Test
Valid values for the hook
swipe position are between
81704 and 105052.
Move to Swipe Position >
Hook Offset 93500