background image

Phase1 - R900 Installation Guide (V2.5 2020-04-16).docx

 

 

Monitor Lamp 

Monitor Lamp LED Error flash code 

 

The Monitor Lamp LED indicates the state of the bill validator by using lighting patterns. 
 

 

 

 

Monitor Lamp 

State 

Description 

 
 

ON 

 
 

OFF 

Communication Error 

Check Connector 

Check Machine Status 

 
 

Flash 1 

OFF 

Active High-Security Mode 

Check the DIP SW setting 

 
 

Flash 2 

 
 

OFF 

Dirty Sensors 

Acceptance Rate <80% 

Need to Clean Sensors 

 
 

Flash >3 

 
 

OFF 

Abnormal Error 

Refer to OP manual 

Contact ASC 

 
 

OFF 

 
 

Flash 1 

Cashbox Out of Position 

Cashbox is Opened 

Close Cashbox 

 
 

OFF 

 
 

Flash 2 

Cashbox Full 

Check Cashbox 

Collect Bills 

 
 

OFF 

 
 

Flash >3 

Sensor Errors 

Check the Sensor Status 

 
 

ON 

 
 

Flash 

Hard Failure 

Contact ASC 

Summary of Contents for R900

Page 1: ...from the vending machine 2 Remove the bill magazine Press forward on the yellow latch on the bill magazine and pull to remove 3 Mount the R900 bill validator on the mounting studs through the opening in the front of the vendor and secure using the included hardware 4 Connect the R900 bill validator to the appropriate interface harness Apply gentle pressure to connect the pins will bend if forced 5...

Page 2: ... 3 4 ON B1 B2 B3 B4 1 2 3 4 ON No ON A1 Description Bill 1 OFF Accepted Inhibited No A2 A3 A4 Bill 2 Bill 3 Bill 4 Accepted Inhibited Accepted Inhibited Accepted Inhibited ON B1 Description Bill 5 OFF Accepted Inhibited B2 B3 B4 Bill 6 Com Speed Security Accepted Inhibited 9600bps 19200bps Standard High A1 A2 A3 A4 1 2 3 4 ON B1 B2 B3 B4 1 2 3 4 ON customizing Bill acceptance The R900 ships from t...

Page 3: ... Active High Security Mode Upon power on when the initial cycle is completed the lamp operates one flash cycle in Green 0 3s 5 times to indicate in high security mode Flashing in Green Every 0 5s In Cleaning Mode Ready to be inserted cleaning sheet to clean up the bill path OFF No Power Communication Error Inhibited All Bills Bill is in Inlet Sensor Busy in validation Abnormal State Turn on Power ...

Page 4: ...ion Error Check Connector Check Machine Status Flash 1 OFF Active High Security Mode Check the DIP SW setting Flash 2 OFF Dirty Sensors Acceptance Rate 80 Need to Clean Sensors Flash 3 OFF Abnormal Error Refer to OP manual Contact ASC OFF Flash 1 Cashbox Out of Position Cashbox is Opened Close Cashbox OFF Flash 2 Cashbox Full Check Cashbox Collect Bills OFF Flash 3 Sensor Errors Check the Sensor S...

Page 5: ...sors Clean the sensors referring to the REGULAR MAINTENANCE Specific bills are not accepted Is the DIP SW setting correctly Set DIP SW to be enabled referring to the ENABLING BILLS Is there any dirt on the validation sensors Clean the sensors referring to the REGULAR MAINTENANCE Poor Acceptance Is the security mode set as High Set DIP SW to be standard referring to the ENABLING BILLS Is there any ...

Page 6: ...cleaning is recommended to maintain high acceptance rates We recommend a regular cleaning maintenance once every 3 6 months If cleaning is required use cleaning sheet under the cleaning mode or use a soft damp cloth Do not use abrasive cleaning products Cleaning Mode Use proper cleaning sheet CPI supported Contact local ASC To enter the Cleaning Mode press the push switch twice The bezel lam start...

Page 7: ...CONTACT U S Crane Payment Innovations CPI Corporate Headquarters 3222 Phoenixville Pike Suite 200 Malvern PA 19355 CranePI com ...

Reviews: