background image

Phase1 - R900 Installation Guide (V2.5 2020-04-16).docx

 

 

Bezel Lamp 

starts Flashing 

Bezel Lamp 

keeps Flashing 

Bezel Lamp 

keeps Flashing 

Use proper cleaning 

sheet CPI supported 

To enter the “Cleaning Mode” 

Press push switch twice 

If the BV is in “Cleaning Mode”, 

the bezel lamp starts flashing 

To enter the “Cleaning Mode” 

Insert cleaning sheet 

into bill insertion slot 

Once completed cleaning for 

bill path and validation sensors, 

the cleaning sheet is 

automatically returned to 

insertion slot 

regular maintenance 

 

The R900 bill validator will not need to be cleaned as often as magnetic sensing bill acceptors. However, regular cleaning is 
recommended to maintain high acceptance rates. We recommend a regular cleaning maintenance once every 3-6 months.  
If cleaning is required, use cleaning sheet under the cleaning mode or use a soft damp cloth. Do not use abrasive cleaning products.  

 

 

Cleaning Mode 

 

Use proper cleaning sheet CPI supported. (Contact local ASC) 

 

To enter the “Cleaning Mode”, press the push switch twice 

 

The bezel lam starts flashing. It means the product is in “Cleaning Mode” 
To cancel the “Cleaning Mode”, press push switch once or leave it for 30 seconds 

 

Insert the cleaning sheet into the bill insertion slot. 
The sheet is pulled inside to start the cleaning operation. 
The sheet moves back and force 3 times to complete bill path and sensor cleaning. 

 

Upon the completion of cleaning, the cleaning sheet is returned to the bill insertion slot. 

Summary of Contents for R900

Page 1: ...from the vending machine 2 Remove the bill magazine Press forward on the yellow latch on the bill magazine and pull to remove 3 Mount the R900 bill validator on the mounting studs through the opening in the front of the vendor and secure using the included hardware 4 Connect the R900 bill validator to the appropriate interface harness Apply gentle pressure to connect the pins will bend if forced 5...

Page 2: ... 3 4 ON B1 B2 B3 B4 1 2 3 4 ON No ON A1 Description Bill 1 OFF Accepted Inhibited No A2 A3 A4 Bill 2 Bill 3 Bill 4 Accepted Inhibited Accepted Inhibited Accepted Inhibited ON B1 Description Bill 5 OFF Accepted Inhibited B2 B3 B4 Bill 6 Com Speed Security Accepted Inhibited 9600bps 19200bps Standard High A1 A2 A3 A4 1 2 3 4 ON B1 B2 B3 B4 1 2 3 4 ON customizing Bill acceptance The R900 ships from t...

Page 3: ... Active High Security Mode Upon power on when the initial cycle is completed the lamp operates one flash cycle in Green 0 3s 5 times to indicate in high security mode Flashing in Green Every 0 5s In Cleaning Mode Ready to be inserted cleaning sheet to clean up the bill path OFF No Power Communication Error Inhibited All Bills Bill is in Inlet Sensor Busy in validation Abnormal State Turn on Power ...

Page 4: ...ion Error Check Connector Check Machine Status Flash 1 OFF Active High Security Mode Check the DIP SW setting Flash 2 OFF Dirty Sensors Acceptance Rate 80 Need to Clean Sensors Flash 3 OFF Abnormal Error Refer to OP manual Contact ASC OFF Flash 1 Cashbox Out of Position Cashbox is Opened Close Cashbox OFF Flash 2 Cashbox Full Check Cashbox Collect Bills OFF Flash 3 Sensor Errors Check the Sensor S...

Page 5: ...sors Clean the sensors referring to the REGULAR MAINTENANCE Specific bills are not accepted Is the DIP SW setting correctly Set DIP SW to be enabled referring to the ENABLING BILLS Is there any dirt on the validation sensors Clean the sensors referring to the REGULAR MAINTENANCE Poor Acceptance Is the security mode set as High Set DIP SW to be standard referring to the ENABLING BILLS Is there any ...

Page 6: ...cleaning is recommended to maintain high acceptance rates We recommend a regular cleaning maintenance once every 3 6 months If cleaning is required use cleaning sheet under the cleaning mode or use a soft damp cloth Do not use abrasive cleaning products Cleaning Mode Use proper cleaning sheet CPI supported Contact local ASC To enter the Cleaning Mode press the push switch twice The bezel lam start...

Page 7: ...CONTACT U S Crane Payment Innovations CPI Corporate Headquarters 3222 Phoenixville Pike Suite 200 Malvern PA 19355 CranePI com ...