IX-4- Input/Output switching type can be set to 
PNP/NPN

The initial factory setting of Input/Output switching type  is set on PNP 
(chap. V): this configuration is to be changed only when NPN switching 
type is required for Input/Output.

1- Pressing 

M

, 6 times 

 Type mode.

2- The 

typ

message confirms that mode. Then, 

Pnp

 is displayed. 

To stay on PNP, press 

M

 to validate.

3- For NPN, press the 

+

 to obtain 

npn

.

Memorization is automatic.

4- Wait for automatic return of 

O0

, vacuum level.

X

2

3

1

4

5

6

7

8

3s

ct3

X - CYCLES / VERSION DISPLAY 

A- Cycle counter

1- Press the 

+

 key for 3s to get into this mode.

2- The display shows 

ct1

 for 2s:

3- The counter (9 digits) scrolls per block of 3 digits (the point 

indicates which block of the digits is displayed). Example: if ct1 = 
006855456 

 

0.06

 for 2s then 

85.5

 for 2s then 

456.

 for 2s.

The counter display loops until pressing the 

M

 key (transition to 

ct2 counter).

4- The display shows 

ct2

, then after 2s the counter value is scrolled 

(the same for ct1).

NOTE :

ct1

 is the number of vacuum external commands (impulses on the 

signal input « Vacuum control » 

 

v  

).

ct2

 is the number of actual activations of the vacuum valve.

The difference between the two counters is used to determine the 
trigger frequency of the ASC control system.

ct3

 is the number of actual activations of the blow-off valve.

B- Firmware version

6- 1 pressing on 

M

 (after display of ct1 and ct2) allows to display 

firmware version.

7- The display shows  

Fir

.

8- The version appears after 2s, example

4.0.2

.

IX-4- Tipo di commutazione ingresso / uscita. Può 
essere impostato PNP/NPN

L'impostazione iniziale di fabbrica del tipo di commutazione Ingresso / 
Uscita è impostata su PNP(cap. V): questa configurazione deve essere 
modificata solo quando NPN è in commutazioneil tipo è richiesto per 
Input / Output.
1- Premere 

M

, 6 volte 

 Tipo di modalità.

2- il messaggio 

typ

 conferma questa modalità.  Quindi 

Pnp

 è 

visualizzato. Per rimanere su PNP, premere 

M

 per confermare.

3- Per NPN, premere il tasto 

+

 per ottenere 

npn

. La memorizzazi-

one è automatica

4- Attendere il ritorno automatico di 

O0

,livello di vuoto.

X - VISUALIZZAZZIONE NUMERO CICLI

A- Contatore di cicli

1- Una pressione della durata di 3 s sul tasto 

+

 permette di entrare in 

questa modalità.

2- Il display indica  

ct1

 poi, dopo 2s:

3- ll contatore (9 cifre) scorre per blocchi di 3 cifre (il punto 

indica il blocco di cifre che viene indicato. Esempio: Se ct1 
= 006855456 

 

0.06

 viene indicato per 2 s, poi 

85.5

 

viene indicato per 2 s, ed infine 

456.

 viene indicato per 2 s.

La visualizzazione del contatore ricomincia fino a che non si preme 
sul tasto 

M

 (passaggio al contatore ct2).

4- Il display indica 

ct2

 poi, dopo 2s, il valore del contatore scorre 

(come per ct1).

NOTA :
il parametro 

ct1

 indica il numero di comandi esterni di vuoto (impulsi 

sull'ingresso del segnale "Comando di vuoto"

v  

).

Il parametro 

ct2

 indica il numero di attivazioni effettive della valvola 

di vuoto.
La differenza tra i 2 contatori permette di determinare quante volte è 
intervenuto il sistema di regolazione ASC, fornendo una indicazione in 
merito alla buona tenuta del circuito di vuoto.

ct3

 è il numero di attivazioni della valvola di controsoffio.

B- Versione Firmware

6- 1 pressione su 

M

 (dopo visualizzazione di ct1 e ct2) permette di 

passare alla visualizzazione della versione di firmware.

7- Il display indica 

Fir

.

8- l'indicazione della versione appare dopo 2s, esempio 

4.0.2

.

Summary of Contents for LEMAX90X B3 Series

Page 1: ...uit maintenance The LEMAX module thus provides the maximum energy saving without any limitations to the performance and functioning of the overall production system The pressure regulator is included on standalone modules only V4 0 2 software Questo documento è destinato a chi utilizza generatori di vuoto LEMAX nelle seguenti versioni LEMAX90X S LEMAX90X SC14 LEMAX90X V Importante Evoluzione della...

Page 2: ...ach module is fed by common pressure covering the whole island see figure 1 LEMFIXA LEMFIXB LEMFIXB 2 DIN 35 3 Ø 4 LEMFIXA Ø 4 64 13 5 Ø 4 2 32 5 10 64 5 18 5 G1 4 F 75 85 25 15 76 29 9 6 7 64 5 71 2 35 DIN LEMFIXA LEMFIXB III II IDENTIFICAZIONE DEL MODULO Per soddisfare tutte le esigenze operative la gamma LEMAX è composta da moduli indipendenti ed isole componibili con logica di comando NC o NO ...

Page 3: ...ion pads is as short as possible Note module s protection Vacuum entry sieve A 200 µ sieve integrated in port B protects the module by stopping any abrasive particle sand Possible additional filter on vacuum circuit In the rare cases of thin dust in wet environment an adequate filter will prevent any clogging see COVAL catalog vacuum circuit filters B ISOLE COMPONIBILI 1 Isole assemblate Se tutti ...

Page 4: ... V PNP NPN BN brown BK black BU blue WH white 24V DC v b 0V DC LEMAX PNP IN 2 WH 4 BK 3 BU LEMAX NPN IN v b 0V DC 2 WH 4 BK 3 BU RL 1 BN 24V DC 5 V DC 1 5V r 0V DC LEMAX PNP OUT 2 WH 4 BK 3 BU RL 1 BN 24V DC r 5 V DC 1 5V 0V DC LEMAX NPN OUT 4 BR 2 WH 3 BU 2 1 4 3 24 V 0 V OUT IN VI IT V CONNESSIONI ELETTRICHE La pompa per vuoto LEMAX richiede l impiego di configurazioni di alimentazione a bassiss...

Page 5: ...put switching type Can be set to PnP by default or nPn see IX 4 Electronic manual override TYPE 3 1 3s 2 4 5 10s Factory Setting COUNTER CMD FW Version AUTO BLOWOFF L1 h1 L2 h2 UNIT DIAG ECO VII SCHEMA SINOTTICO DELLE FUNZIONI Bloccaggio sbloccaggio tastiera UnL Loc vedere IX B Comandi manuali servoassistiti vedere VIII Ritorno all impostazione di default FAC vedere XII 4 Visualizzazione del numer...

Page 6: ... 1 2 1 IX 2s 2 3 1 x3 4 5 5s IX 1 IX CONFIGURAZIONE Il modulo si configura utilizzando il display e la tastiera Possono essere configurate 3 funzioni Unità di Misura IX 1 Uscita ausiliaria IX 2 Controsoffio IX 3 Modalità di commutazione degli ingressi sorpassi parametrici PNP NPN IX 4 A Accensione All accensione del modulo sul display compare 1 Visualizzazione 8 8 8 per la durata di o 5s 2 Indicaz...

Page 7: ... return of O0 vacuum level IX 2 Uscita ausiliaria Non disponibile nella versione LEMAX90X SC14 L impostazione per il PIN2 del connettore OUT cap V è regolata inizialmente impostazione di default sull opzione B2 segnale analogico livello di vuoto da 1 a 5 VCC Questa impostazione può essere cambiata solo per utilizzare l opzione B1 segnale senza ASC 5V On Off 1 Premere 4 volte il pulsante M 2 Il mes...

Page 8: ...niziale di fabbrica del tipo di commutazione Ingresso Uscita è impostata su PNP cap V questa configurazione deve essere modificata solo quando NPN è in commutazioneil tipo è richiesto per Input Output 1 Premere M 6 volte Tipo di modalità 2 il messaggio typ conferma questa modalità Quindi Pnp è visualizzato Per rimanere su PNP premere M per confermare 3 Per NPN premere il tasto per ottenere npn La ...

Page 9: ...ns Diagram B shows how by increasing h2 vacuum regeneration that may prevent ASC are avoided XI AVVISI DURANTE IL CICLO Il funzionamento in modalità ASC permette il massimo risparmio energetico dal 60 al 99 in funzione dell applicazione L ASC si disattiva automaticamente in caso di prodotti porosi cap I Con prodotti a tenuta il funzionamento ASC si disattiva solo in caso di trafilamenti nelle vent...

Page 10: ...postazione attuale 65 4 Utilizzando e selezionare il valore desiderato Da 0 a 99 se l unità di misura è di vuoto uni Pct Da 0 a 29 9 inHg se l unità di misura sono i pollici di mercurio uni iH Da 0 a 990 mbar se l unità di misura sono i millibar uni bA Il nuovo valore viene automaticamente memorizzato poi si ritorna alla visualizzazione del livello di vuoto 00 OPPURE per impostare h1 isteresi di L...

Page 11: ...ttivazione della funzione DIAG ECO In caso l applicazione lo richieda la funzione DIAG ECO può essere disattivata 1 Premere 4 volte il pulsante M 2 La visualizzazione del parametro Eco permette di verificare il settaggio della funzione di ECOnomizzazione dell aria compressa L impostazione di default prevede che la funzione sia attiva e che dopo 2s on venga visualizzato automaticamente 3 Selezionar...

Page 12: ...rso di manipolazione comando di vuoto attivo Controllare il processo di manipolazione Come cambiare la modalità di funzionamento da NO standard a NO i 1 Prodotto senza corrente Tieni premuti i tasti M e 2 Attaccare la corrente e rilasciare i tasti 3 Viene visualizzata la modalità operativa selezionata in fabbrica no 4 Premere o per selezionare la modalità noi 5 Confermare premendo il tasto M XIV P...

Page 13: ...nima moduli indipendenti 4 5 bar isole componibili 4 bar Controsoffio regolabile moduli indipendenti P 3 5 bar Isole componibili pressione di alimentazione Vuoto massimo 85 Portata aspirata da 29 a 70 Nl min Consumo da 44 a 90 Nl min durante funzionamento senza ASC Grado di protezione IP65 Frequenza massima di lavoro 4 Hz Durata 30 milioni di cicli Peso 130 g Temperatura di lavoro da 10 a 60 C Mat...

Reviews: