background image

- 13 -

© COVAL - v6 - 05/2019 - The diagrams are not contractual.
The range and the products characteristics may be modified by COVAL without notice.

XV - REMINDER FOR SPECIFICATIONS

General characteristics

 Non lubricated air, filtered 5 microns relevant to ISO 8573-1:2010 

[4:5:4] standard. 

 Optimal working pressure: 4.5 to 7 bar.

 Mini dynamic pressure :   - stand-alone module: 4,5 bar.

 

- island modules: 4 bar.

 Blow-off: adjustable flow: - stand-alone modules: P = 3.5 bar.

 

- island modules: P supply.

 Maximum vacuum: 85%.

 Suction flow rate: From 29 to 70 Nl/min (1.02 to 2.47 SCFM).

 Air consumption: From 44 to 90 Nl/min (1.55 to 3.18 SCFM), when 

operating “without ASC”.

 Electrical degree of protection: IP65.

 Maximum frequency of utilization: 4 Hz.

 Number of operations: 30 million cycles.

 Weight: 130 g.

 Working temperature: from 10 to 60°C (50 to 140°F).

 Materials: PA 6-6 15%FG, brass, aluminium, NBR.

Integrated silencer

 Sound level: about 68 dBA "without ASC", 0 dBA with ASC.

 Clog free open silencer.

Electrical controls

 Controls voltage: 24 V DC (adjustable ± 10 % ) PNP or NPN.

 Current draw: 30 mA (0,7W) vacuum or blow-off.

Integrated electronics

 Supply: 24 V DC ; current draw: <57mA. 

 Measure range: 0 to 99 % vacuum.

 Measure precision: ±1.5 % of the range, temperature compensated.

 Adjustable hysteresis: 0% to 100%.

 Display: 3 digit digital display.

Service characteristics

 "Gripped product" output signal

- 24V DC NO switching output, power: 125 mA PNP or NPN.

 Configurable auxiliary output: 

- either "without ASC" 5V DC NO switching output.
- or "vacuum level" signal, analogic O to 5V DC, along the 0 to 99% 

vacuum measure range.

XVI - PERFORMANCE FOR GRIPPING 
 PHASE

Lowering L1 reduces gripping time (chap. XI). The table is a guide for 
the optimum L1 setting : it gives the emptying time for 1 liter volume, 
up to a given L1 vacuum threshold.
One can see that gripping is shorter:
- with a minimum volume to be evacuated as mentioned in the table 

for 1l.

- with a vacuum level L1 set to the level just enough to ensure a safe 

object grip.

www.coval.com

The LEMAX instructions are available in PDF version in different 
languages on our website.

XV - CARATTERISTICHE

Generali

 Alimentazione: aria non lubrificata, filtrazione 5 micron secondo 

norma ISO 8573-1:2010 [4:5:4]. 

 Pressione di lavoro: da 4.5 a 7 bar.

 Pressione dinamica minima: - moduli indipendenti: 4,5 bar.

 

 

- isole componibili: 4 bar.

 Controsoffio: regolabile:

  - moduli indipendenti: P = 3,5 bar.
  - Isole componibili: pressione di alimentazione.

 Vuoto massimo: 85%.

 Portata aspirata: da 29 a 70 Nl/min.

 Consumo: da 44 a 90 Nl/min durante funzionamento senza ASC.

 Grado di protezione: IP65.

 Frequenza massima di lavoro: 4 Hz.

 Durata: 30 milioni di cicli.

 Peso: 130 g.

 Temperatura di lavoro: da 10 a 60° C.

 Materiali: PA 6-6 15% FV, ottone, alluminio, NBR.

Silenziatore integrato

 Rumorosità: circa 68 dBA senza ASC, 0 dBA con ASC.

 Silenziatore passante non intasabile integrato.

Elettriche

 Tensione di alimentazione: 24 VDC (+- 10%) PNP o NPN.

 Assorbimento: 30 mA (0,7 W) (elettrovalvole di alimentazione e 

controsoffio).

Sensore di vuoto

 Alimentazione: 24VDC, assorbimento <57mA.

 Campo di misura: da 0 a 99% di vuoto.

 Precisione: +/- 1,5% del fondo scala, compensato in temperatura.

 Isteresi regolabile: da 0 a 100%.

 Display a 3 cifre, 7 segmenti.

Uscite

 Uscita “presenza pezzo”:

- 24 VDC, uscita NO, corrente massima: 125 mA PNP o NPN.

 Uscita ausiliaria configurabile:

- “ASC disattivato”: +5V DC, segnale On/Off, NO.
- Oppure uscita analogica 1-5 VDC proporzionale al grado di vuoto 

(0-99%).

XVI - PRESTAZIONI IN ASPIRAZIONE

Riducendo L1 si riduce il tempo di presa (cap. XI). La tabella è una 
guida per la scelta del valore migliore di L1: fornisce il tempo di 
svuotamento di un volume unitario (1 litro) ai diversi gradi di vuoto.

Si noti come il tempo si riduca:
- Riducendo il volume da svuotare minimo, rispetto al riferimento di 1 

l della tabella.

- Riducendo il grado di vuoto L1 regolato al valore minimo necessario 

per una presa di pezzo sicura.

www.coval.com

Le istruzioni di servizio LEMAX sono disponibili in versione PDF sul 
nostro sito Web nelle diversi lingue.

© COVAL - v6 - 05/2019 - I dati forniti non sono vincolanti.
COVAL si riserva la possibilità di modificare la gamma e le caratteristiche dei prodotti senza preavviso.

Emptying time for 1 liter volume

Tempo di svuotamento (volume = 1 litro)

1.0 mm

1.2 mm

1.4 mm

LEMAX 90 X 

10

 

  

   

12

    

   

14

55%

1.76 s

1.13 s

0.73 s

60%

2.04 s

1.31 s

0.85 s

65%

2.38 s

1.53 s

0.99 s

70%

2.80 s

1.80 s

1.16 s

75%

3.33 s

2.15 s

1.38 s

80%

4.09 s

2.64 s

1.70 s

Air consumption

(without ASC)

Consumo di aria

(senza ASC)

29

 Nl/mn

1.02

 SCFM

44

 Nl/mn

1.55

 SCFM

65

 Nl/mn

2.30

 SCFM

90

 Nl/mn

3.18

 SCFM

45

 Nl/mn

1.59

 SCFM

70

 Nl/mn

2.47

 SCFM

Air suction

Portata aspirata

Vacuum level L1 required for gripping

Livello di vuoto L1 richiesto per la presa

nozzle size

Taglia eiettore

Summary of Contents for LEMAX90X B3 Series

Page 1: ...uit maintenance The LEMAX module thus provides the maximum energy saving without any limitations to the performance and functioning of the overall production system The pressure regulator is included on standalone modules only V4 0 2 software Questo documento è destinato a chi utilizza generatori di vuoto LEMAX nelle seguenti versioni LEMAX90X S LEMAX90X SC14 LEMAX90X V Importante Evoluzione della...

Page 2: ...ach module is fed by common pressure covering the whole island see figure 1 LEMFIXA LEMFIXB LEMFIXB 2 DIN 35 3 Ø 4 LEMFIXA Ø 4 64 13 5 Ø 4 2 32 5 10 64 5 18 5 G1 4 F 75 85 25 15 76 29 9 6 7 64 5 71 2 35 DIN LEMFIXA LEMFIXB III II IDENTIFICAZIONE DEL MODULO Per soddisfare tutte le esigenze operative la gamma LEMAX è composta da moduli indipendenti ed isole componibili con logica di comando NC o NO ...

Page 3: ...ion pads is as short as possible Note module s protection Vacuum entry sieve A 200 µ sieve integrated in port B protects the module by stopping any abrasive particle sand Possible additional filter on vacuum circuit In the rare cases of thin dust in wet environment an adequate filter will prevent any clogging see COVAL catalog vacuum circuit filters B ISOLE COMPONIBILI 1 Isole assemblate Se tutti ...

Page 4: ... V PNP NPN BN brown BK black BU blue WH white 24V DC v b 0V DC LEMAX PNP IN 2 WH 4 BK 3 BU LEMAX NPN IN v b 0V DC 2 WH 4 BK 3 BU RL 1 BN 24V DC 5 V DC 1 5V r 0V DC LEMAX PNP OUT 2 WH 4 BK 3 BU RL 1 BN 24V DC r 5 V DC 1 5V 0V DC LEMAX NPN OUT 4 BR 2 WH 3 BU 2 1 4 3 24 V 0 V OUT IN VI IT V CONNESSIONI ELETTRICHE La pompa per vuoto LEMAX richiede l impiego di configurazioni di alimentazione a bassiss...

Page 5: ...put switching type Can be set to PnP by default or nPn see IX 4 Electronic manual override TYPE 3 1 3s 2 4 5 10s Factory Setting COUNTER CMD FW Version AUTO BLOWOFF L1 h1 L2 h2 UNIT DIAG ECO VII SCHEMA SINOTTICO DELLE FUNZIONI Bloccaggio sbloccaggio tastiera UnL Loc vedere IX B Comandi manuali servoassistiti vedere VIII Ritorno all impostazione di default FAC vedere XII 4 Visualizzazione del numer...

Page 6: ... 1 2 1 IX 2s 2 3 1 x3 4 5 5s IX 1 IX CONFIGURAZIONE Il modulo si configura utilizzando il display e la tastiera Possono essere configurate 3 funzioni Unità di Misura IX 1 Uscita ausiliaria IX 2 Controsoffio IX 3 Modalità di commutazione degli ingressi sorpassi parametrici PNP NPN IX 4 A Accensione All accensione del modulo sul display compare 1 Visualizzazione 8 8 8 per la durata di o 5s 2 Indicaz...

Page 7: ... return of O0 vacuum level IX 2 Uscita ausiliaria Non disponibile nella versione LEMAX90X SC14 L impostazione per il PIN2 del connettore OUT cap V è regolata inizialmente impostazione di default sull opzione B2 segnale analogico livello di vuoto da 1 a 5 VCC Questa impostazione può essere cambiata solo per utilizzare l opzione B1 segnale senza ASC 5V On Off 1 Premere 4 volte il pulsante M 2 Il mes...

Page 8: ...niziale di fabbrica del tipo di commutazione Ingresso Uscita è impostata su PNP cap V questa configurazione deve essere modificata solo quando NPN è in commutazioneil tipo è richiesto per Input Output 1 Premere M 6 volte Tipo di modalità 2 il messaggio typ conferma questa modalità Quindi Pnp è visualizzato Per rimanere su PNP premere M per confermare 3 Per NPN premere il tasto per ottenere npn La ...

Page 9: ...ns Diagram B shows how by increasing h2 vacuum regeneration that may prevent ASC are avoided XI AVVISI DURANTE IL CICLO Il funzionamento in modalità ASC permette il massimo risparmio energetico dal 60 al 99 in funzione dell applicazione L ASC si disattiva automaticamente in caso di prodotti porosi cap I Con prodotti a tenuta il funzionamento ASC si disattiva solo in caso di trafilamenti nelle vent...

Page 10: ...postazione attuale 65 4 Utilizzando e selezionare il valore desiderato Da 0 a 99 se l unità di misura è di vuoto uni Pct Da 0 a 29 9 inHg se l unità di misura sono i pollici di mercurio uni iH Da 0 a 990 mbar se l unità di misura sono i millibar uni bA Il nuovo valore viene automaticamente memorizzato poi si ritorna alla visualizzazione del livello di vuoto 00 OPPURE per impostare h1 isteresi di L...

Page 11: ...ttivazione della funzione DIAG ECO In caso l applicazione lo richieda la funzione DIAG ECO può essere disattivata 1 Premere 4 volte il pulsante M 2 La visualizzazione del parametro Eco permette di verificare il settaggio della funzione di ECOnomizzazione dell aria compressa L impostazione di default prevede che la funzione sia attiva e che dopo 2s on venga visualizzato automaticamente 3 Selezionar...

Page 12: ...rso di manipolazione comando di vuoto attivo Controllare il processo di manipolazione Come cambiare la modalità di funzionamento da NO standard a NO i 1 Prodotto senza corrente Tieni premuti i tasti M e 2 Attaccare la corrente e rilasciare i tasti 3 Viene visualizzata la modalità operativa selezionata in fabbrica no 4 Premere o per selezionare la modalità noi 5 Confermare premendo il tasto M XIV P...

Page 13: ...nima moduli indipendenti 4 5 bar isole componibili 4 bar Controsoffio regolabile moduli indipendenti P 3 5 bar Isole componibili pressione di alimentazione Vuoto massimo 85 Portata aspirata da 29 a 70 Nl min Consumo da 44 a 90 Nl min durante funzionamento senza ASC Grado di protezione IP65 Frequenza massima di lavoro 4 Hz Durata 30 milioni di cicli Peso 130 g Temperatura di lavoro da 10 a 60 C Mat...

Reviews: